power: supply: charger-manager: Fix trivial language typos

Fix few trivial language typos.

Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Krzysztof Kozlowski 2019-01-08 13:12:12 +01:00 committed by Sebastian Reichel
parent fd10606f93
commit 02276af2fc

View file

@ -4,7 +4,7 @@
*
* This driver enables to monitor battery health and control charger
* during suspend-to-mem.
* Charger manager depends on other devices. register this later than
* Charger manager depends on other devices. Register this later than
* the depending devices.
*
* This program is free software; you can redistribute it and/or modify
@ -29,7 +29,7 @@
#include <linux/thermal.h>
/*
* Default termperature threshold for charging.
* Default temperature threshold for charging.
* Every temperature units are in tenth of centigrade.
*/
#define CM_DEFAULT_RECHARGE_TEMP_DIFF 50
@ -356,7 +356,7 @@ static bool is_polling_required(struct charger_manager *cm)
* Note that Charger Manager keeps the charger enabled regardless whether
* the charger is charging or not (because battery is full or no external
* power source exists) except when CM needs to disable chargers forcibly
* bacause of emergency causes; when the battery is overheated or too cold.
* because of emergency causes; when the battery is overheated or too cold.
*/
static int try_charger_enable(struct charger_manager *cm, bool enable)
{
@ -643,7 +643,7 @@ static int cm_check_thermal_status(struct charger_manager *cm)
if (ret) {
/* FIXME:
* No information of battery temperature might
* occur hazadous result. We have to handle it
* occur hazardous result. We have to handle it
* depending on battery type.
*/
dev_err(cm->dev, "Failed to get battery temperature\n");
@ -693,7 +693,7 @@ static bool _cm_monitor(struct charger_manager *cm)
uevent_notify(cm, default_event_names[temp_alrt]);
/*
* Check whole charging duration and discharing duration
* Check whole charging duration and discharging duration
* after full-batt.
*/
} else if (!cm->emergency_stop && check_charging_duration(cm)) {
@ -866,7 +866,7 @@ static void battout_handler(struct charger_manager *cm)
}
/**
* misc_event_handler - Handler for other evnets
* misc_event_handler - Handler for other events
* @cm: the Charger Manager representing the battery.
* @type: the Charger Manager representing the battery.
*/
@ -1218,7 +1218,7 @@ static int charger_extcon_init(struct charger_manager *cm,
}
/**
* charger_manager_register_extcon - Register extcon device to recevie state
* charger_manager_register_extcon - Register extcon device to receive state
* of charger cable.
* @cm: the Charger Manager representing the battery.
*
@ -1538,7 +1538,7 @@ static struct charger_desc *of_cm_parse_desc(struct device *dev)
of_property_read_u32(np, "cm-discharging-max",
&desc->discharging_max_duration_ms);
/* battery charger regualtors */
/* battery charger regulators */
desc->num_charger_regulators = of_get_child_count(np);
if (desc->num_charger_regulators) {
struct charger_regulator *chg_regs;
@ -1801,7 +1801,7 @@ static int charger_manager_probe(struct platform_device *pdev)
/*
* Charger-manager have to check the charging state right after
* tialization of charger-manager and then update current charging
* initialization of charger-manager and then update current charging
* state.
*/
cm_monitor();