mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git
synced 2024-10-14 12:37:32 +00:00
dt-bindings: mtd: convert "fixed-partitions" to the json-schema
This standardizes its documentation, allows validating with Makefile checks and helps writing DTS files. Noticeable changes: 1. Dropped "Partitions can be represented by sub-nodes of a flash device." as we also support subpartitions (don't have to be part of flash device node) 2. Dropped "to Linux" as bindings are meant to be os agnostic. Signed-off-by: Rafał Miłecki <rafal@milecki.pl> Link: https://lore.kernel.org/r/20201210172352.31632-1-zajec5@gmail.com Signed-off-by: Rob Herring <robh@kernel.org>
This commit is contained in:
parent
60a2a8ff33
commit
04e9ab7526
2 changed files with 154 additions and 129 deletions
|
@ -24,137 +24,10 @@ another partitioning method.
|
|||
Available bindings are listed in the "partitions" subdirectory.
|
||||
|
||||
|
||||
Fixed Partitions
|
||||
================
|
||||
|
||||
Partitions can be represented by sub-nodes of a flash device. This can be used
|
||||
on platforms which have strong conventions about which portions of a flash are
|
||||
used for what purposes, but which don't use an on-flash partition table such
|
||||
as RedBoot.
|
||||
|
||||
The partition table should be a subnode of the flash node and should be named
|
||||
'partitions'. This node should have the following property:
|
||||
- compatible : (required) must be "fixed-partitions"
|
||||
Partitions are then defined in subnodes of the partitions node.
|
||||
Deprecated: partitions defined in flash node
|
||||
============================================
|
||||
|
||||
For backwards compatibility partitions as direct subnodes of the flash device are
|
||||
supported. This use is discouraged.
|
||||
NOTE: also for backwards compatibility, direct subnodes that have a compatible
|
||||
string are not considered partitions, as they may be used for other bindings.
|
||||
|
||||
#address-cells & #size-cells must both be present in the partitions subnode of the
|
||||
flash device. There are two valid values for both:
|
||||
<1>: for partitions that require a single 32-bit cell to represent their
|
||||
size/address (aka the value is below 4 GiB)
|
||||
<2>: for partitions that require two 32-bit cells to represent their
|
||||
size/address (aka the value is 4 GiB or greater).
|
||||
|
||||
Required properties:
|
||||
- reg : The partition's offset and size within the flash
|
||||
|
||||
Optional properties:
|
||||
- label : The label / name for this partition. If omitted, the label is taken
|
||||
from the node name (excluding the unit address).
|
||||
- read-only : This parameter, if present, is a hint to Linux that this
|
||||
partition should only be mounted read-only. This is usually used for flash
|
||||
partitions containing early-boot firmware images or data which should not be
|
||||
clobbered.
|
||||
- lock : Do not unlock the partition at initialization time (not supported on
|
||||
all devices)
|
||||
- slc-mode: This parameter, if present, allows one to emulate SLC mode on a
|
||||
partition attached to an MLC NAND thus making this partition immune to
|
||||
paired-pages corruptions
|
||||
|
||||
Examples:
|
||||
|
||||
|
||||
flash@0 {
|
||||
partitions {
|
||||
compatible = "fixed-partitions";
|
||||
#address-cells = <1>;
|
||||
#size-cells = <1>;
|
||||
|
||||
partition@0 {
|
||||
label = "u-boot";
|
||||
reg = <0x0000000 0x100000>;
|
||||
read-only;
|
||||
};
|
||||
|
||||
uimage@100000 {
|
||||
reg = <0x0100000 0x200000>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
flash@1 {
|
||||
partitions {
|
||||
compatible = "fixed-partitions";
|
||||
#address-cells = <1>;
|
||||
#size-cells = <2>;
|
||||
|
||||
/* a 4 GiB partition */
|
||||
partition@0 {
|
||||
label = "filesystem";
|
||||
reg = <0x00000000 0x1 0x00000000>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
flash@2 {
|
||||
partitions {
|
||||
compatible = "fixed-partitions";
|
||||
#address-cells = <2>;
|
||||
#size-cells = <2>;
|
||||
|
||||
/* an 8 GiB partition */
|
||||
partition@0 {
|
||||
label = "filesystem #1";
|
||||
reg = <0x0 0x00000000 0x2 0x00000000>;
|
||||
};
|
||||
|
||||
/* a 4 GiB partition */
|
||||
partition@200000000 {
|
||||
label = "filesystem #2";
|
||||
reg = <0x2 0x00000000 0x1 0x00000000>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
flash@3 {
|
||||
partitions {
|
||||
compatible = "fixed-partitions";
|
||||
#address-cells = <1>;
|
||||
#size-cells = <1>;
|
||||
|
||||
partition@0 {
|
||||
label = "bootloader";
|
||||
reg = <0x000000 0x100000>;
|
||||
read-only;
|
||||
};
|
||||
|
||||
firmware@100000 {
|
||||
label = "firmware";
|
||||
reg = <0x100000 0xe00000>;
|
||||
compatible = "brcm,trx";
|
||||
};
|
||||
|
||||
calibration@f00000 {
|
||||
label = "calibration";
|
||||
reg = <0xf00000 0x100000>;
|
||||
compatible = "fixed-partitions";
|
||||
ranges = <0 0xf00000 0x100000>;
|
||||
#address-cells = <1>;
|
||||
#size-cells = <1>;
|
||||
|
||||
partition@0 {
|
||||
label = "wifi0";
|
||||
reg = <0x000000 0x080000>;
|
||||
};
|
||||
|
||||
partition@80000 {
|
||||
label = "wifi1";
|
||||
reg = <0x080000 0x080000>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
|
|
|
@ -0,0 +1,152 @@
|
|||
# SPDX-License-Identifier: GPL-2.0-only OR BSD-2-Clause
|
||||
%YAML 1.2
|
||||
---
|
||||
$id: http://devicetree.org/schemas/mtd/partitions/fixed-partitions.yaml#
|
||||
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
||||
|
||||
title: Fixed partitions
|
||||
|
||||
description: |
|
||||
This binding can be used on platforms which have strong conventions about
|
||||
which portions of a flash are used for what purposes, but which don't use an
|
||||
on-flash partition table such as RedBoot.
|
||||
|
||||
The partition table should be a node named "partitions". Partitions are then
|
||||
defined as subnodes.
|
||||
|
||||
maintainers:
|
||||
- Rafał Miłecki <rafal@milecki.pl>
|
||||
|
||||
properties:
|
||||
compatible:
|
||||
const: fixed-partitions
|
||||
|
||||
"#address-cells": true
|
||||
|
||||
"#size-cells": true
|
||||
|
||||
patternProperties:
|
||||
"@[0-9a-f]+$":
|
||||
description: node describing a single flash partition
|
||||
type: object
|
||||
|
||||
properties:
|
||||
reg:
|
||||
description: partition's offset and size within the flash
|
||||
maxItems: 1
|
||||
|
||||
label:
|
||||
description: The label / name for this partition. If omitted, the label
|
||||
is taken from the node name (excluding the unit address).
|
||||
|
||||
read-only:
|
||||
description: This parameter, if present, is a hint that this partition
|
||||
should only be mounted read-only. This is usually used for flash
|
||||
partitions containing early-boot firmware images or data which should
|
||||
not be clobbered.
|
||||
type: boolean
|
||||
|
||||
lock:
|
||||
description: Do not unlock the partition at initialization time (not
|
||||
supported on all devices)
|
||||
type: boolean
|
||||
|
||||
slc-mode:
|
||||
description: This parameter, if present, allows one to emulate SLC mode
|
||||
on a partition attached to an MLC NAND thus making this partition
|
||||
immune to paired-pages corruptions
|
||||
type: boolean
|
||||
|
||||
required:
|
||||
- reg
|
||||
|
||||
required:
|
||||
- "#address-cells"
|
||||
- "#size-cells"
|
||||
|
||||
additionalProperties: true
|
||||
|
||||
examples:
|
||||
- |
|
||||
partitions {
|
||||
compatible = "fixed-partitions";
|
||||
#address-cells = <1>;
|
||||
#size-cells = <1>;
|
||||
|
||||
partition@0 {
|
||||
label = "u-boot";
|
||||
reg = <0x0000000 0x100000>;
|
||||
read-only;
|
||||
};
|
||||
|
||||
uimage@100000 {
|
||||
reg = <0x0100000 0x200000>;
|
||||
};
|
||||
};
|
||||
- |
|
||||
partitions {
|
||||
compatible = "fixed-partitions";
|
||||
#address-cells = <1>;
|
||||
#size-cells = <2>;
|
||||
|
||||
/* a 4 GiB partition */
|
||||
partition@0 {
|
||||
label = "filesystem";
|
||||
reg = <0x00000000 0x1 0x00000000>;
|
||||
};
|
||||
};
|
||||
- |
|
||||
partitions {
|
||||
compatible = "fixed-partitions";
|
||||
#address-cells = <2>;
|
||||
#size-cells = <2>;
|
||||
|
||||
/* an 8 GiB partition */
|
||||
partition@0 {
|
||||
label = "filesystem #1";
|
||||
reg = <0x0 0x00000000 0x2 0x00000000>;
|
||||
};
|
||||
|
||||
/* a 4 GiB partition */
|
||||
partition@200000000 {
|
||||
label = "filesystem #2";
|
||||
reg = <0x2 0x00000000 0x1 0x00000000>;
|
||||
};
|
||||
};
|
||||
- |
|
||||
partitions {
|
||||
compatible = "fixed-partitions";
|
||||
#address-cells = <1>;
|
||||
#size-cells = <1>;
|
||||
|
||||
partition@0 {
|
||||
label = "bootloader";
|
||||
reg = <0x000000 0x100000>;
|
||||
read-only;
|
||||
};
|
||||
|
||||
firmware@100000 {
|
||||
compatible = "brcm,trx";
|
||||
label = "firmware";
|
||||
reg = <0x100000 0xe00000>;
|
||||
};
|
||||
|
||||
calibration@f00000 {
|
||||
compatible = "fixed-partitions";
|
||||
label = "calibration";
|
||||
reg = <0xf00000 0x100000>;
|
||||
ranges = <0 0xf00000 0x100000>;
|
||||
#address-cells = <1>;
|
||||
#size-cells = <1>;
|
||||
|
||||
partition@0 {
|
||||
label = "wifi0";
|
||||
reg = <0x000000 0x080000>;
|
||||
};
|
||||
|
||||
partition@80000 {
|
||||
label = "wifi1";
|
||||
reg = <0x080000 0x080000>;
|
||||
};
|
||||
};
|
||||
};
|
Loading…
Reference in a new issue