ABI: sysfs-class-hwmon: document emergency/max/min temperature alarms
These attributes are widely used in the hwmon subsystem, but they still must be documented. Add tempY_emergency_alarm, tempY_max_alarm and tempY_min_alarm to the ABI documentation according to their current usage and access rights in the hwmon subsystem. Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com> Link: https://lore.kernel.org/r/20231116-hwmon_abi-v1-4-8bfb7f51145a@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
2de83b67cf
commit
16693c2725
|
@ -381,6 +381,15 @@ Description:
|
|||
|
||||
RW
|
||||
|
||||
What: /sys/class/hwmon/hwmonX/tempY_max_alarm
|
||||
Description:
|
||||
Maximum temperature alarm flag.
|
||||
|
||||
- 0: OK
|
||||
- 1: temperature has reached tempY_max
|
||||
|
||||
RO
|
||||
|
||||
What: /sys/class/hwmon/hwmonX/tempY_min
|
||||
Description:
|
||||
Temperature min value.
|
||||
|
@ -389,6 +398,15 @@ Description:
|
|||
|
||||
RW
|
||||
|
||||
What: /sys/class/hwmon/hwmonX/tempY_min_alarm
|
||||
Description:
|
||||
Minimum temperature alarm flag.
|
||||
|
||||
- 0: OK
|
||||
- 1: temperature has reached tempY_min
|
||||
|
||||
RO
|
||||
|
||||
What: /sys/class/hwmon/hwmonX/tempY_max_hyst
|
||||
Description:
|
||||
Temperature hysteresis value for max limit.
|
||||
|
@ -457,6 +475,15 @@ Description:
|
|||
|
||||
RW
|
||||
|
||||
What: /sys/class/hwmon/hwmonX/tempY_emergency_alarm
|
||||
Description:
|
||||
Emergency high temperature alarm flag.
|
||||
|
||||
- 0: OK
|
||||
- 1: temperature has reached tempY_emergency
|
||||
|
||||
RO
|
||||
|
||||
What: /sys/class/hwmon/hwmonX/tempY_emergency_hyst
|
||||
Description:
|
||||
Temperature hysteresis value for emergency limit.
|
||||
|
|