ABI: sysfs-class-hwmon: document emergency/max/min temperature alarms

These attributes are widely used in the hwmon subsystem, but they still
must be documented.

Add tempY_emergency_alarm, tempY_max_alarm and tempY_min_alarm to the
ABI documentation according to their current usage and access rights in
the hwmon subsystem.

Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com>
Link: https://lore.kernel.org/r/20231116-hwmon_abi-v1-4-8bfb7f51145a@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
Javier Carrasco 2023-11-17 07:40:37 +01:00 committed by Guenter Roeck
parent 2de83b67cf
commit 16693c2725
1 changed files with 27 additions and 0 deletions

View File

@ -381,6 +381,15 @@ Description:
RW
What: /sys/class/hwmon/hwmonX/tempY_max_alarm
Description:
Maximum temperature alarm flag.
- 0: OK
- 1: temperature has reached tempY_max
RO
What: /sys/class/hwmon/hwmonX/tempY_min
Description:
Temperature min value.
@ -389,6 +398,15 @@ Description:
RW
What: /sys/class/hwmon/hwmonX/tempY_min_alarm
Description:
Minimum temperature alarm flag.
- 0: OK
- 1: temperature has reached tempY_min
RO
What: /sys/class/hwmon/hwmonX/tempY_max_hyst
Description:
Temperature hysteresis value for max limit.
@ -457,6 +475,15 @@ Description:
RW
What: /sys/class/hwmon/hwmonX/tempY_emergency_alarm
Description:
Emergency high temperature alarm flag.
- 0: OK
- 1: temperature has reached tempY_emergency
RO
What: /sys/class/hwmon/hwmonX/tempY_emergency_hyst
Description: