phylink: Improve error message when validate failed

This should improve the error message when the PHY validate in the MAC
driver failed. I ran into this problem multiple times that I put wrong
interface values into the device tree and was searching why it is
failing with -22 (-EINVAL). This should make it easier to spot the
problem.

Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Acked-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Hauke Mehrtens 2020-03-02 00:55:02 +01:00 committed by David S. Miller
parent 43de81b060
commit 20d8bb0d17

View file

@ -761,8 +761,14 @@ static int phylink_bringup_phy(struct phylink *pl, struct phy_device *phy,
config.interface = interface;
ret = phylink_validate(pl, supported, &config);
if (ret)
if (ret) {
phylink_warn(pl, "validation of %s with support %*pb and advertisement %*pb failed: %d\n",
phy_modes(config.interface),
__ETHTOOL_LINK_MODE_MASK_NBITS, phy->supported,
__ETHTOOL_LINK_MODE_MASK_NBITS, config.advertising,
ret);
return ret;
}
phy->phylink = pl;
phy->phy_link_change = phylink_phy_change;