From 21d90eda433f5d39930ca7133340225b8fb7940f Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?Micha=C5=82=20Miros=C5=82aw?= Date: Mon, 4 May 2020 21:47:45 +0200 Subject: [PATCH] power: bq25890: fix ADC mode configuration MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit Datasheet describes two modes for reading ADC measurements: 1. continuous, 1 Hz - enabled and started by CONV_RATE bit 2. one-shot - triggered by CONV_START bit In continuous mode, CONV_START is read-only and signifies an ongoing conversion. Change the code to follow the datasheet and really disable continuous mode for power saving. Signed-off-by: Michał Mirosław Signed-off-by: Sebastian Reichel --- drivers/power/supply/bq25890_charger.c | 31 +++++++++++++++++++++----- 1 file changed, 26 insertions(+), 5 deletions(-) diff --git a/drivers/power/supply/bq25890_charger.c b/drivers/power/supply/bq25890_charger.c index 08d31ed4bc27..c9f7877ded95 100644 --- a/drivers/power/supply/bq25890_charger.c +++ b/drivers/power/supply/bq25890_charger.c @@ -126,6 +126,7 @@ static const struct regmap_access_table bq25890_writeable_regs = { static const struct regmap_range bq25890_volatile_reg_ranges[] = { regmap_reg_range(0x00, 0x00), + regmap_reg_range(0x02, 0x02), regmap_reg_range(0x09, 0x09), regmap_reg_range(0x0b, 0x14), }; @@ -374,18 +375,38 @@ enum bq25890_chrg_fault { CHRG_FAULT_TIMER_EXPIRED, }; +static bool bq25890_is_adc_property(enum power_supply_property psp) +{ + switch (psp) { + case POWER_SUPPLY_PROP_VOLTAGE_NOW: + case POWER_SUPPLY_PROP_CURRENT_NOW: + return true; + + default: + return false; + } +} + static int bq25890_power_supply_get_property(struct power_supply *psy, enum power_supply_property psp, union power_supply_propval *val) { - int ret; struct bq25890_device *bq = power_supply_get_drvdata(psy); struct bq25890_state state; + bool do_adc_conv; + int ret; mutex_lock(&bq->lock); state = bq->state; + do_adc_conv = !state.online && bq25890_is_adc_property(psp); + if (do_adc_conv) + bq25890_field_write(bq, F_CONV_START, 1); mutex_unlock(&bq->lock); + if (do_adc_conv) + regmap_field_read_poll_timeout(bq->rmap_fields[F_CONV_START], + ret, !ret, 25000, 1000000); + switch (psp) { case POWER_SUPPLY_PROP_STATUS: if (!state.online) @@ -623,8 +644,8 @@ static int bq25890_hw_init(struct bq25890_device *bq) } } - /* Configure ADC for continuous conversions. This does not enable it. */ - ret = bq25890_field_write(bq, F_CONV_RATE, 1); + /* Configure ADC for continuous conversions when charging */ + ret = bq25890_field_write(bq, F_CONV_RATE, !!bq->state.online); if (ret < 0) { dev_dbg(bq->dev, "Config ADC failed %d\n", ret); return ret; @@ -966,7 +987,7 @@ static int bq25890_suspend(struct device *dev) * If charger is removed, while in suspend, make sure ADC is diabled * since it consumes slightly more power. */ - return bq25890_field_write(bq, F_CONV_START, 0); + return bq25890_field_write(bq, F_CONV_RATE, 0); } static int bq25890_resume(struct device *dev) @@ -982,7 +1003,7 @@ static int bq25890_resume(struct device *dev) /* Re-enable ADC only if charger is plugged in. */ if (bq->state.online) { - ret = bq25890_field_write(bq, F_CONV_START, 1); + ret = bq25890_field_write(bq, F_CONV_RATE, 1); if (ret < 0) goto unlock; }