clk: qcom: apss-ipq-pll: Use stromer plus ops for stromer plus pll

The set rate and determine rate operations are different between
Stromer and Stromer Plus PLLs. Since the programming sequence is
different, the PLLs dont get configured properly and random,
inexplicable crash/freeze is seen. Hence, use stromer plus ops
for ipq_pll_stromer_plus.

Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org>
Acked-by: Stephen Boyd <sboyd@kernel.org>
Fixes: c7ef7fbb1c ("clk: qcom: apss-ipq-pll: add support for IPQ5332")
Signed-off-by: Kathiravan T <quic_kathirav@quicinc.com>
Signed-off-by: Varadarajan Narayanan <quic_varada@quicinc.com>
Link: https://lore.kernel.org/r/c86ecaa23dc4f39650bcf4a3bd54a617a932e4fd.1697781921.git.quic_varada@quicinc.com
Signed-off-by: Bjorn Andersson <andersson@kernel.org>
This commit is contained in:
Varadarajan Narayanan 2023-10-20 11:49:33 +05:30 committed by Bjorn Andersson
parent 84da48921a
commit 267e291984

View file

@ -68,7 +68,7 @@ static struct clk_alpha_pll ipq_pll_stromer_plus = {
.fw_name = "xo",
},
.num_parents = 1,
.ops = &clk_alpha_pll_stromer_ops,
.ops = &clk_alpha_pll_stromer_plus_ops,
},
},
};