dt-bindings:iio:temperature:maxim_thermocouple.txt to maxim,max31855k.yaml
Given we already have another maxim thermocouple driver that isn't covered by this binding it seems a better idea to chose to name it after a specific part. I added an additional example for the maxim,max6755 to illustrate the need for spi-cpha for that part. Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Reviewed-by: Rob Herring <robh@kernel.org> Acked-by: Matt Ranostay <matt.ranostay@konsulko.com> Link: https://lore.kernel.org/r/20201031134110.724233-29-jic23@kernel.org
This commit is contained in:
parent
17d1ffdfb6
commit
29a702dcf4
2 changed files with 76 additions and 24 deletions
|
@ -0,0 +1,76 @@
|
||||||
|
# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
|
||||||
|
%YAML 1.2
|
||||||
|
---
|
||||||
|
$id: http://devicetree.org/schemas/iio/temperature/maxim,max31855k.yaml#
|
||||||
|
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
||||||
|
|
||||||
|
title: Maxim MAX31855 and similar thermocouples
|
||||||
|
|
||||||
|
maintainers:
|
||||||
|
- Matt Ranostay <matt.ranostay@konsulko.com>
|
||||||
|
|
||||||
|
description: |
|
||||||
|
https://datasheets.maximintegrated.com/en/ds/MAX6675.pdf
|
||||||
|
https://datasheets.maximintegrated.com/en/ds/MAX31855.pdf
|
||||||
|
|
||||||
|
properties:
|
||||||
|
compatible:
|
||||||
|
description:
|
||||||
|
The generic maxim,max31855 compatible is deprecated in favour of
|
||||||
|
the thermocouple type specific variants.
|
||||||
|
enum:
|
||||||
|
- maxim,max6675
|
||||||
|
- maxim,max31855
|
||||||
|
- maxim,max31855k
|
||||||
|
- maxim,max31855j
|
||||||
|
- maxim,max31855n
|
||||||
|
- maxim,max31855s
|
||||||
|
- maxim,max31855t
|
||||||
|
- maxim,max31855e
|
||||||
|
- maxim,max31855r
|
||||||
|
|
||||||
|
reg:
|
||||||
|
maxItems: 1
|
||||||
|
|
||||||
|
spi-max-frequency: true
|
||||||
|
spi-cpha: true
|
||||||
|
|
||||||
|
required:
|
||||||
|
- compatible
|
||||||
|
- reg
|
||||||
|
|
||||||
|
allOf:
|
||||||
|
- if:
|
||||||
|
properties:
|
||||||
|
compatible:
|
||||||
|
contains:
|
||||||
|
enum:
|
||||||
|
- maxim,max6675
|
||||||
|
then:
|
||||||
|
required:
|
||||||
|
- spi-cpha
|
||||||
|
else:
|
||||||
|
properties:
|
||||||
|
spi-cpha: false
|
||||||
|
|
||||||
|
additionalProperties: false
|
||||||
|
|
||||||
|
examples:
|
||||||
|
- |
|
||||||
|
spi {
|
||||||
|
#address-cells = <1>;
|
||||||
|
#size-cells = <0>;
|
||||||
|
|
||||||
|
temp-sensor@0 {
|
||||||
|
compatible = "maxim,max31855k";
|
||||||
|
reg = <0>;
|
||||||
|
spi-max-frequency = <4300000>;
|
||||||
|
};
|
||||||
|
temp-sensor@1 {
|
||||||
|
compatible = "maxim,max6675";
|
||||||
|
reg = <1>;
|
||||||
|
spi-max-frequency = <4300000>;
|
||||||
|
spi-cpha;
|
||||||
|
};
|
||||||
|
};
|
||||||
|
...
|
|
@ -1,24 +0,0 @@
|
||||||
Maxim thermocouple support
|
|
||||||
|
|
||||||
* https://datasheets.maximintegrated.com/en/ds/MAX6675.pdf
|
|
||||||
* https://datasheets.maximintegrated.com/en/ds/MAX31855.pdf
|
|
||||||
|
|
||||||
Required properties:
|
|
||||||
|
|
||||||
- compatible: must be "maxim,max6675" or one of the following:
|
|
||||||
"maxim,max31855k", "maxim,max31855j", "maxim,max31855n",
|
|
||||||
"maxim,max31855s", "maxim,max31855t", "maxim,max31855e",
|
|
||||||
"maxim,max31855r"; the generic "max,max31855" is deprecated.
|
|
||||||
- reg: SPI chip select number for the device
|
|
||||||
- spi-max-frequency: must be 4300000
|
|
||||||
- spi-cpha: must be defined for max6675 to enable SPI mode 1
|
|
||||||
|
|
||||||
Refer to spi/spi-bus.txt for generic SPI slave bindings.
|
|
||||||
|
|
||||||
Example:
|
|
||||||
|
|
||||||
max31855@0 {
|
|
||||||
compatible = "maxim,max31855k";
|
|
||||||
reg = <0>;
|
|
||||||
spi-max-frequency = <4300000>;
|
|
||||||
};
|
|
Loading…