staging: spi: mt7621: Use macros instead of hardcoded values

This patch uses macros instead of hardcoded values for the SPI_MASTER
register access in mt7621_spi_reset() and mt7621_spi_prepare().

Signed-off-by: Stefan Roese <sr@denx.de>
Cc: Mark Brown <broonie@kernel.org>
Cc: Sankalp Negi <sankalpnegi2310@gmail.com>
Cc: Chuanhong Guo <gch981213@gmail.com>
Cc: John Crispin <john@phrozen.org>
Reviewed-by: NeilBrown <neil@brown.name>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Stefan Roese 2019-02-01 11:17:14 +01:00 committed by Greg Kroah-Hartman
parent 376a622021
commit 5220dd4f94

View file

@ -37,6 +37,12 @@
#define SPI_CTL_START BIT(8)
#define MT7621_SPI_MASTER 0x28
#define MASTER_MORE_BUFMODE BIT(2)
#define MASTER_FULL_DUPLEX BIT(10)
#define MASTER_RS_CLK_SEL GENMASK(27, 16)
#define MASTER_RS_CLK_SEL_SHIFT 16
#define MASTER_RS_SLAVE_SEL GENMASK(31, 29)
#define MT7621_SPI_MOREBUF 0x2c
#define MT7621_SPI_POLAR 0x38
#define MT7621_SPI_SPACE 0x3c
@ -77,9 +83,13 @@ static void mt7621_spi_reset(struct mt7621_spi *rs)
{
u32 master = mt7621_spi_read(rs, MT7621_SPI_MASTER);
master |= 7 << 29;
master |= 1 << 2;
master &= ~(1 << 10);
/*
* Select SPI device 7, enable "more buffer mode" and disable
* full-duplex (only half-duplex really works on this chip
* reliably)
*/
master |= MASTER_RS_SLAVE_SEL | MASTER_MORE_BUFMODE;
master &= ~MASTER_FULL_DUPLEX;
mt7621_spi_write(rs, MT7621_SPI_MASTER, master);
rs->pending_write = 0;
@ -115,8 +125,8 @@ static int mt7621_spi_prepare(struct spi_device *spi, unsigned int speed)
rate = 2;
reg = mt7621_spi_read(rs, MT7621_SPI_MASTER);
reg &= ~(0xfff << 16);
reg |= (rate - 2) << 16;
reg &= ~MASTER_RS_CLK_SEL;
reg |= (rate - 2) << MASTER_RS_CLK_SEL_SHIFT;
rs->speed = speed;
reg &= ~MT7621_LSB_FIRST;