Bluetooth: hci_sync: Fix using the same interval and window for Coded PHY

Coded PHY recommended intervals are 3 time bigger than the 1M PHY so
this aligns with that by multiplying by 3 the values given to 1M PHY
since the code already used recommended values for that.

Fixes: 288c90224e ("Bluetooth: Enable all supported LE PHY by default")
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
This commit is contained in:
Luiz Augusto von Dentz 2024-03-28 15:58:10 -04:00
parent b37cab587a
commit 53cb4197e6
1 changed files with 3 additions and 3 deletions

View File

@ -2814,8 +2814,8 @@ static int hci_le_set_ext_scan_param_sync(struct hci_dev *hdev, u8 type,
if (qos->bcast.in.phy & BT_ISO_PHY_CODED) {
cp->scanning_phys |= LE_SCAN_PHY_CODED;
hci_le_scan_phy_params(phy, type,
interval,
window);
interval * 3,
window * 3);
num_phy++;
phy++;
}
@ -2835,7 +2835,7 @@ static int hci_le_set_ext_scan_param_sync(struct hci_dev *hdev, u8 type,
if (scan_coded(hdev)) {
cp->scanning_phys |= LE_SCAN_PHY_CODED;
hci_le_scan_phy_params(phy, type, interval, window);
hci_le_scan_phy_params(phy, type, interval * 3, window * 3);
num_phy++;
phy++;
}