ALSA: bebob: delete workaround for protocol version 3

In a commit c4d860a0d2 ("ALSA: bebob: loosen up severity of checking
continuity for BeBoB v3 quirk"), a workaround was added for the quirk in
BeBoB protocol version 3 against the discontinuity of data block counter.
As long as seeing with sequence replay for media clock recovery, such
quirk disappears.

This commit deletes the workaround.

Signed-off-by: Takashi Sakamoto <o-takashi@sakamocchi.jp>
Link: https://lore.kernel.org/r/20210611035003.26852-3-o-takashi@sakamocchi.jp
Signed-off-by: Takashi Iwai <tiwai@suse.de>
This commit is contained in:
Takashi Sakamoto 2021-06-11 12:50:02 +09:00 committed by Takashi Iwai
parent c66c630499
commit 82fb3bf92c
3 changed files with 0 additions and 17 deletions

View file

@ -75,7 +75,6 @@ name_device(struct snd_bebob *bebob)
u32 hw_id;
u32 data[2] = {0};
u32 revision;
u32 version;
int err;
/* get vendor name from root directory */
@ -108,12 +107,6 @@ name_device(struct snd_bebob *bebob)
if (err < 0)
goto end;
err = snd_bebob_read_quad(bebob->unit, INFO_OFFSET_BEBOB_VERSION,
&version);
if (err < 0)
goto end;
bebob->version = version;
strcpy(bebob->card->driver, "BeBoB");
strcpy(bebob->card->shortname, model);
strcpy(bebob->card->mixername, model);

View file

@ -109,8 +109,6 @@ struct snd_bebob {
/* for M-Audio special devices */
void *maudio_special_quirk;
/* For BeBoB version quirk. */
unsigned int version;
bool discontinuity_quirk;
struct amdtp_domain domain;

View file

@ -456,14 +456,6 @@ static int init_stream(struct snd_bebob *bebob, struct amdtp_stream *stream)
}
if (stream == &bebob->tx_stream) {
// BeBoB v3 transfers packets with these qurks:
// - In the beginning of streaming, the value of dbc is
// incremented even if no data blocks are transferred.
// - The value of dbc is reset suddenly.
if (bebob->version > 2)
bebob->tx_stream.flags |= CIP_EMPTY_HAS_WRONG_DBC |
CIP_SKIP_DBC_ZERO_CHECK;
// At high sampling rate, M-Audio special firmware transmits
// empty packet with the value of dbc incremented by 8 but the
// others are valid to IEC 61883-1.