PCI: Disable D3cold on Asus B1400 PCI-NVMe bridge
[ Upstream commit cdea98bf1f
]
The Asus B1400 with original shipped firmware versions and VMD disabled
cannot resume from suspend: the NVMe device becomes unresponsive and
inaccessible.
This appears to be an untested D3cold transition by the vendor; Intel
socwatch shows that Windows leaves the NVMe device and parent bridge in D0
during suspend, even though these firmware versions have StorageD3Enable=1.
The NVMe device and parent PCI bridge both share the same "PXP" ACPI power
resource, which gets turned off as both devices are put into D3cold during
suspend. The _OFF() method calls DL23() which sets a L23E bit at offset
0xe2 into the PCI configuration space for this root port. This is the
specific write that the _ON() routine is unable to recover from. This
register is not documented in the public chipset datasheet.
Disallow D3cold on the PCI bridge to enable successful suspend/resume.
Link: https://bugzilla.kernel.org/show_bug.cgi?id=215742
Link: https://lore.kernel.org/r/20240228075316.7404-1-drake@endlessos.org
Signed-off-by: Daniel Drake <drake@endlessos.org>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
Acked-by: Jian-Hong Pan <jhp@endlessos.org>
Acked-by: Rafael J. Wysocki <rafael@kernel.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
parent
73bdf8d41c
commit
8466112999
1 changed files with 48 additions and 0 deletions
|
@ -907,6 +907,54 @@ static void chromeos_fixup_apl_pci_l1ss_capability(struct pci_dev *dev)
|
|||
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x5ad6, chromeos_save_apl_pci_l1ss_capability);
|
||||
DECLARE_PCI_FIXUP_RESUME(PCI_VENDOR_ID_INTEL, 0x5ad6, chromeos_fixup_apl_pci_l1ss_capability);
|
||||
|
||||
/*
|
||||
* Disable D3cold on Asus B1400 PCI-NVMe bridge
|
||||
*
|
||||
* On this platform with VMD off, the NVMe device cannot successfully power
|
||||
* back on from D3cold. This appears to be an untested transition by the
|
||||
* vendor: Windows leaves the NVMe and parent bridge in D0 during suspend.
|
||||
*
|
||||
* We disable D3cold on the parent bridge for simplicity, and the fact that
|
||||
* both parent bridge and NVMe device share the same power resource.
|
||||
*
|
||||
* This is only needed on BIOS versions before 308; the newer versions flip
|
||||
* StorageD3Enable from 1 to 0.
|
||||
*/
|
||||
static const struct dmi_system_id asus_nvme_broken_d3cold_table[] = {
|
||||
{
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
|
||||
DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.304"),
|
||||
},
|
||||
},
|
||||
{
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
|
||||
DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.305"),
|
||||
},
|
||||
},
|
||||
{
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
|
||||
DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.306"),
|
||||
},
|
||||
},
|
||||
{
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
|
||||
DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.307"),
|
||||
},
|
||||
},
|
||||
{}
|
||||
};
|
||||
|
||||
static void asus_disable_nvme_d3cold(struct pci_dev *pdev)
|
||||
{
|
||||
if (dmi_check_system(asus_nvme_broken_d3cold_table) > 0)
|
||||
pci_d3cold_disable(pdev);
|
||||
}
|
||||
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x9a09, asus_disable_nvme_d3cold);
|
||||
|
||||