ARM: zynq: DT: Migrate UART to Cadence binding

The Zynq UART is Cadence IP and the driver has been renamed accordingly.
Migrate the DT to use the new binding for the UART driver.

Signed-off-by: Soren Brinkmann <soren.brinkmann@xilinx.com>
Acked-by: Peter Crosthwaite <peter.crosthwaite@xilinx.com>
Acked-by: Rob Herring <robh@kernel.org>
Tested-by: Michal Simek <michal.simek@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
This commit is contained in:
Soren Brinkmann 2014-04-04 17:23:45 -07:00 committed by Michal Simek
parent db34d2b32f
commit 8fe9346b94
1 changed files with 4 additions and 4 deletions

View File

@ -105,19 +105,19 @@
};
uart0: serial@e0000000 {
compatible = "xlnx,xuartps";
compatible = "xlnx,xuartps", "cdns,uart-r1p8";
status = "disabled";
clocks = <&clkc 23>, <&clkc 40>;
clock-names = "ref_clk", "aper_clk";
clock-names = "uart_clk", "pclk";
reg = <0xE0000000 0x1000>;
interrupts = <0 27 4>;
};
uart1: serial@e0001000 {
compatible = "xlnx,xuartps";
compatible = "xlnx,xuartps", "cdns,uart-r1p8";
status = "disabled";
clocks = <&clkc 24>, <&clkc 41>;
clock-names = "ref_clk", "aper_clk";
clock-names = "uart_clk", "pclk";
reg = <0xE0001000 0x1000>;
interrupts = <0 50 4>;
};