ARM: plat-samsung: use Kconfig choice for debug UART selection

Now that the DEBUG_LL UART can be selected by a Kconfig choice, convert
the Samsung UART selection to use a set of bools rather than an int.

Acked-by: Nicolas Pitre <nicolas.pitre@linaro.org>
Signed-off-by: Will Deacon <will.deacon@arm.com>
This commit is contained in:
Will Deacon 2011-08-16 22:28:54 +01:00
parent f73765fcb8
commit 952aeeb288
2 changed files with 40 additions and 12 deletions

View file

@ -128,6 +128,39 @@ choice
Say Y here if you want the debug print routines to direct
their output to the second serial port on these devices.
config DEBUG_S3C_UART0
depends on PLAT_SAMSUNG
bool "Use S3C UART 0 for low-level debug"
help
Say Y here if you want the debug print routines to direct
their output to UART 0. The port must have been initialised
by the boot-loader before use.
The uncompressor code port configuration is now handled
by CONFIG_S3C_LOWLEVEL_UART_PORT.
config DEBUG_S3C_UART1
depends on PLAT_SAMSUNG
bool "Use S3C UART 1 for low-level debug"
help
Say Y here if you want the debug print routines to direct
their output to UART 1. The port must have been initialised
by the boot-loader before use.
The uncompressor code port configuration is now handled
by CONFIG_S3C_LOWLEVEL_UART_PORT.
config DEBUG_S3C_UART2
depends on PLAT_SAMSUNG
bool "Use S3C UART 2 for low-level debug"
help
Say Y here if you want the debug print routines to direct
their output to UART 2. The port must have been initialised
by the boot-loader before use.
The uncompressor code port configuration is now handled
by CONFIG_S3C_LOWLEVEL_UART_PORT.
endchoice
config EARLY_PRINTK
@ -146,16 +179,4 @@ config OC_ETM
buffer driver that will allow you to collect traces of the
kernel code.
config DEBUG_S3C_UART
depends on PLAT_SAMSUNG
int "S3C UART to use for low-level debug"
default "0"
help
Choice for UART for kernel low-level using S3C UARTS,
should be between zero and two. The port must have been
initialised by the boot-loader before use.
The uncompressor code port configuration is now handled
by CONFIG_S3C_LOWLEVEL_UART_PORT.
endmenu

View file

@ -367,4 +367,11 @@ config SAMSUNG_PD
help
Say Y here if you want to control Power Domain by Runtime PM.
config DEBUG_S3C_UART
depends on PLAT_SAMSUNG
int
default "0" if DEBUG_S3C_UART0
default "1" if DEBUG_S3C_UART1
default "2" if DEBUG_S3C_UART2
endif