i2c: exynos5: Avoid transaction timeouts due TRANSFER_DONE_AUTO not set

After commit 7999eecb7e ("i2c: exynos5: fix arbitration lost handling"),
some I2C transactions are failing because the TRANSFER_DONE_AUTO field is
not set in the I2C_TRANS_STATUS register so the i2c->status value is left
to -EINVAL causing the i2c->msg_complete completion to never be signaled.

For example, when reading the time of an I2C rtc on an Exynos5800 machine:

$ cat /sys/class/rtc/rtc0/time
[   25.924594] exynos5-hsi2c 12e10000.i2c: rx timeout
[   65.028365] max77686-rtc max77802-rtc: Fail to read time reg(-22)
cat: /sys/class/rtc/rtc0/time: Invalid argument

The Exynos5422 manual states clearly that most I2C_TRANS_STATUS reg bits
(including TRANSFER_DONE_AUTO) are cleared after the register is read. So
reading has side effects and should only be done if HSI2C_INT_I2C was set.

Fixes: 7999eecb7e ("i2c: exynos5: fix arbitration lost handling")
Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com>
Reviewed-by: Andrzej Hajda <a.hajda@samsung.com>
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
This commit is contained in:
Javier Martinez Canillas 2017-03-09 11:05:33 -03:00 committed by Wolfram Sang
parent ab809fd81f
commit 9ad2247442

View file

@ -457,7 +457,6 @@ static irqreturn_t exynos5_i2c_irq(int irqno, void *dev_id)
int_status = readl(i2c->regs + HSI2C_INT_STATUS);
writel(int_status, i2c->regs + HSI2C_INT_STATUS);
trans_status = readl(i2c->regs + HSI2C_TRANS_STATUS);
/* handle interrupt related to the transfer status */
if (i2c->variant->hw == HSI2C_EXYNOS7) {
@ -482,11 +481,13 @@ static irqreturn_t exynos5_i2c_irq(int irqno, void *dev_id)
goto stop;
}
trans_status = readl(i2c->regs + HSI2C_TRANS_STATUS);
if ((trans_status & HSI2C_MASTER_ST_MASK) == HSI2C_MASTER_ST_LOSE) {
i2c->state = -EAGAIN;
goto stop;
}
} else if (int_status & HSI2C_INT_I2C) {
trans_status = readl(i2c->regs + HSI2C_TRANS_STATUS);
if (trans_status & HSI2C_NO_DEV_ACK) {
dev_dbg(i2c->dev, "No ACK from device\n");
i2c->state = -ENXIO;