cxlflash: Fix to escalate LINK_RESET also on port 1

The original fix to escalate a 'login timed out' error to a LINK_RESET
was only made for one of the two ports on the card. This fix resolves
the same issue for the second port (port 1).

Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Acked-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Reviewed-by: Uma Krishnan <ukrishn@linux.vnet.ibm.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
Manoj Kumar 2015-12-14 14:55:09 -06:00 committed by Martin K. Petersen
parent 03996f2064
commit a9be294ecb

View file

@ -1108,7 +1108,7 @@ static const struct asyc_intr_info ainfo[] = {
{SISL_ASTATUS_FC1_OTHER, "other error", 1, CLR_FC_ERROR | LINK_RESET},
{SISL_ASTATUS_FC1_LOGO, "target initiated LOGO", 1, 0},
{SISL_ASTATUS_FC1_CRC_T, "CRC threshold exceeded", 1, LINK_RESET},
{SISL_ASTATUS_FC1_LOGI_R, "login timed out, retrying", 1, 0},
{SISL_ASTATUS_FC1_LOGI_R, "login timed out, retrying", 1, LINK_RESET},
{SISL_ASTATUS_FC1_LOGI_F, "login failed", 1, CLR_FC_ERROR},
{SISL_ASTATUS_FC1_LOGI_S, "login succeeded", 1, SCAN_HOST},
{SISL_ASTATUS_FC1_LINK_DN, "link down", 1, 0},