power: charger-manager: Check charging state right after completed initialization

This patch check the charging state after completed initialization of charger-
manager and update current charging state. If charger-manager never check and
update current charging state, charger-manager would have the mismatch issue
between real state of cable connection and the charging state of charger-manager
until first polling time of charger-manager.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Acked-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Sebastian Reichel <sre@kernel.org>
This commit is contained in:
Chanwoo Choi 2014-08-26 13:41:39 +09:00 committed by Sebastian Reichel
parent c6738d06a3
commit b1022e2478
1 changed files with 7 additions and 0 deletions

View File

@ -1839,6 +1839,13 @@ static int charger_manager_probe(struct platform_device *pdev)
device_init_wakeup(&pdev->dev, true);
device_set_wakeup_capable(&pdev->dev, false);
/*
* Charger-manager have to check the charging state right after
* tialization of charger-manager and then update current charging
* state.
*/
cm_monitor();
schedule_work(&setup_polling);
return 0;