hwmon: (lm90) Prevent integer underflows of temperature calculations

The min/max/crit and all other temperature values that are passed to
the driver are unlimited and value that is close to INT_MIN results in
integer underflow of the temperature calculations made by the driver
for LM99 sensor. Temperature hysteresis is among those values that need
to be limited, but limiting of hysteresis is independent from the sensor
version. Add the missing limits.

Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Link: https://lore.kernel.org/r/20210623042231.16008-2-digetx@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
Dmitry Osipenko 2021-06-23 07:22:30 +03:00 committed by Guenter Roeck
parent 4c7f85a321
commit b50aa49638
1 changed files with 11 additions and 2 deletions

View File

@ -1029,8 +1029,11 @@ static int lm90_set_temp11(struct lm90_data *data, int index, long val)
int err;
/* +16 degrees offset for temp2 for the LM99 */
if (data->kind == lm99 && index <= 2)
if (data->kind == lm99 && index <= 2) {
/* prevent integer underflow */
val = max(val, -128000l);
val -= 16000;
}
if (data->kind == adt7461 || data->kind == tmp451)
data->temp11[index] = temp_to_u16_adt7461(data, val);
@ -1089,8 +1092,11 @@ static int lm90_set_temp8(struct lm90_data *data, int index, long val)
int err;
/* +16 degrees offset for temp2 for the LM99 */
if (data->kind == lm99 && index == 3)
if (data->kind == lm99 && index == 3) {
/* prevent integer underflow */
val = max(val, -128000l);
val -= 16000;
}
if (data->kind == adt7461 || data->kind == tmp451)
data->temp8[index] = temp_to_u8_adt7461(data, val);
@ -1137,6 +1143,9 @@ static int lm90_set_temphyst(struct lm90_data *data, long val)
else
temp = temp_from_s8(data->temp8[LOCAL_CRIT]);
/* prevent integer underflow */
val = max(val, -128000l);
data->temp_hyst = hyst_to_reg(temp - val);
err = i2c_smbus_write_byte_data(client, LM90_REG_W_TCRIT_HYST,
data->temp_hyst);