mmc: dw_mmc: fix mmc_test by not sending abort for DRTO/EBE errors

The STOP command can terminate a data transfer between a memory card and
mmc controller.

As show in Synopsys DesignWare Cores Mobile Storage Host Databook:
Data timeout and Data end-bit error will terminate further data transfer
by mmc controller. So we should not send abort command to terminate a
data transfer again if we got DRTO and EBE interrupt.

After this patch, all mmc_test cases can pass on RK3288-Pink2 board.

Signed-off-by: Addy Ke <addy.ke@rock-chips.com>
Reviewed-by: Doug Anderson <dianders@chromium.org>
Tested-by: Doug Anderson <dianders@chromium.org>
Tested-by: Javier Martinez Canillas <javier.martinez@collabora.co.uk>
Signed-off-by: Jaehoon Chung <jh80.chung@samsung.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
This commit is contained in:
addy ke 2015-02-20 10:55:25 +08:00 committed by Ulf Hansson
parent 6d53200b51
commit bdb9a90b3d

View file

@ -1534,7 +1534,10 @@ static void dw_mci_tasklet_func(unsigned long priv)
if (test_and_clear_bit(EVENT_DATA_ERROR,
&host->pending_events)) {
dw_mci_stop_dma(host);
send_stop_abort(host, data);
if (data->stop ||
!(host->data_status & (SDMMC_INT_DRTO |
SDMMC_INT_EBE)))
send_stop_abort(host, data);
state = STATE_DATA_ERROR;
break;
}
@ -1561,7 +1564,10 @@ static void dw_mci_tasklet_func(unsigned long priv)
if (test_and_clear_bit(EVENT_DATA_ERROR,
&host->pending_events)) {
dw_mci_stop_dma(host);
send_stop_abort(host, data);
if (data->stop ||
!(host->data_status & (SDMMC_INT_DRTO |
SDMMC_INT_EBE)))
send_stop_abort(host, data);
state = STATE_DATA_ERROR;
break;
}