diff --git a/Documentation/devicetree/bindings/regulator/max77802.txt b/Documentation/devicetree/bindings/regulator/max77802.txt index 5aeaffc0f1f0..79e5476444f7 100644 --- a/Documentation/devicetree/bindings/regulator/max77802.txt +++ b/Documentation/devicetree/bindings/regulator/max77802.txt @@ -25,6 +25,29 @@ with their hardware counterparts as follow. The valid names are: example: LDO1, LDO2, LDO35. -BUCKn : for BUCKs, where n can lie in range 1 to 10. example: BUCK1, BUCK5, BUCK10. + +The max77802 regulator supports two different operating modes: Normal and Low +Power Mode. Some regulators support the modes to be changed at startup or by +the consumers during normal operation while others only support to change the +mode during system suspend. The standard regulator suspend states binding can +be used to configure the regulator operating mode. + +The regulators that support the standard "regulator-initial-mode" property, +changing their mode during normal operation are: LDOs 1, 3, 20 and 21. + +The possible values for "regulator-initial-mode" and "regulator-mode" are: + 1: Normal regulator voltage output mode. + 3: Low Power which reduces the quiescent current down to only 1uA + +The list of valid modes are defined in the dt-bindings/clock/maxim,max77802.h +header and can be included by device tree source files. + +The standard "regulator-mode" property can only be used for regulators that +support changing their mode to Low Power Mode during suspend. These regulators +are: BUCKs 2-4 and LDOs 1-35. Also, it only takes effect if the regulator has +been enabled for the given suspend state using "regulator-on-in-suspend" and +has not been disabled for that state using "regulator-off-in-suspend". + Example: max77802@09 { @@ -36,11 +59,23 @@ Example: #size-cells = <0>; regulators { + ldo1_reg: LDO1 { + regulator-name = "vdd_1v0"; + regulator-min-microvolt = <1000000>; + regulator-max-microvolt = <1000000>; + regulator-always-on; + regulator-initial-mode = ; + }; + ldo11_reg: LDO11 { regulator-name = "vdd_ldo11"; regulator-min-microvolt = <1900000>; regulator-max-microvolt = <1900000>; regulator-always-on; + regulator-state-mem { + regulator-on-in-suspend; + regulator-mode = ; + }; }; buck1_reg: BUCK1 {