ARM: at91/dt: sam9260: correct external trigger value

The external trigger value is 0b1101 which is 13 but 0xd.

Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Signed-off-by: Nicolas Ferre <nicolas.ferre@atmel.com>
This commit is contained in:
Alexandre Belloni 2014-05-12 18:32:55 +02:00 committed by Nicolas Ferre
parent 35d35aae81
commit c1ff0b474c

View file

@ -641,7 +641,7 @@ trigger@2 {
trigger@3 {
reg = <3>;
trigger-name = "external";
trigger-value = <0x13>;
trigger-value = <0xd>;
trigger-external;
};
};