iio: adc: ad7192: use devm_clk_get_optional() for mclk

The devm_clk_get_optional() helper returns NULL when devm_clk_get() returns
-ENOENT.
This makes things slightly cleaner. The added benefit is mostly cosmetic.

Also, a minor detail with this call, is that the reference for the parent
device is taken as `spi->dev` instead of `&st->sd.spi->dev` (which looks a
little quirky).

Signed-off-by: Alexandru Ardelean <aardelean@deviqon.com>
Link: https://lore.kernel.org/r/20210513120752.90074-10-aardelean@deviqon.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Alexandru Ardelean 2021-05-13 15:07:49 +03:00 committed by Jonathan Cameron
parent e50aab18dd
commit c9ec2cb328

View file

@ -326,7 +326,7 @@ static int ad7192_of_clock_select(struct ad7192_state *st)
clock_sel = AD7192_CLK_INT;
/* use internal clock */
if (PTR_ERR(st->mclk) == -ENOENT) {
if (st->mclk) {
if (of_property_read_bool(np, "adi,int-clock-output-enable"))
clock_sel = AD7192_CLK_INT_CO;
} else {
@ -978,8 +978,8 @@ static int ad7192_probe(struct spi_device *spi)
st->fclk = AD7192_INT_FREQ_MHZ;
st->mclk = devm_clk_get(&st->sd.spi->dev, "mclk");
if (IS_ERR(st->mclk) && PTR_ERR(st->mclk) != -ENOENT) {
st->mclk = devm_clk_get_optional(&spi->dev, "mclk");
if (IS_ERR(st->mclk)) {
ret = PTR_ERR(st->mclk);
goto error_remove_trigger;
}