ARM: dts: exynos: add a specific compatible to MCT
One compatible is used for the Multi-Core Timer on most of the Samsung Exynos SoCs, which is correct but not specific enough. These MCT blocks have different number of interrupts, so add a second specific compatible to Exynos3250 and all Exynos5 SoCs. Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Reviewed-by: Alim Akhtar <alim.akhtar@samsung.com> Link: https://lore.kernel.org/r/20220304122424.307885-3-krzysztof.kozlowski@canonical.com
This commit is contained in:
parent
c3d3727c85
commit
cca50a59f6
|
@ -269,7 +269,8 @@
|
|||
};
|
||||
|
||||
timer@10050000 {
|
||||
compatible = "samsung,exynos4210-mct";
|
||||
compatible = "samsung,exynos3250-mct",
|
||||
"samsung,exynos4210-mct";
|
||||
reg = <0x10050000 0x800>;
|
||||
interrupts = <GIC_SPI 218 IRQ_TYPE_LEVEL_HIGH>,
|
||||
<GIC_SPI 219 IRQ_TYPE_LEVEL_HIGH>,
|
||||
|
|
|
@ -245,7 +245,8 @@
|
|||
};
|
||||
|
||||
timer@101c0000 {
|
||||
compatible = "samsung,exynos4210-mct";
|
||||
compatible = "samsung,exynos5250-mct",
|
||||
"samsung,exynos4210-mct";
|
||||
reg = <0x101C0000 0x800>;
|
||||
clocks = <&clock CLK_FIN_PLL>, <&clock CLK_MCT>;
|
||||
clock-names = "fin_pll", "mct";
|
||||
|
|
|
@ -333,7 +333,8 @@
|
|||
};
|
||||
|
||||
mct: timer@100b0000 {
|
||||
compatible = "samsung,exynos4210-mct";
|
||||
compatible = "samsung,exynos5260-mct",
|
||||
"samsung,exynos4210-mct";
|
||||
reg = <0x100B0000 0x1000>;
|
||||
clocks = <&fin_pll>, <&clock_peri PERI_CLK_MCT>;
|
||||
clock-names = "fin_pll", "mct";
|
||||
|
|
|
@ -74,7 +74,8 @@
|
|||
};
|
||||
|
||||
mct: timer@101c0000 {
|
||||
compatible = "samsung,exynos4210-mct";
|
||||
compatible = "samsung,exynos5420-mct",
|
||||
"samsung,exynos4210-mct";
|
||||
reg = <0x101c0000 0xb00>;
|
||||
interrupts-extended = <&combiner 23 3>,
|
||||
<&combiner 23 4>,
|
||||
|
|
Loading…
Reference in New Issue