net: phy: mxl-gpy: print firmware in human readable form

Now having a major and a minor number, also print the firmware in
human readable form "major.minor". Still keep the 4-digit hexadecimal
representation because that form is used in the firmware changelog
documents. Also, drop the "release" string assuming that most common
case, but make it clearer that the user is running a test version.

Signed-off-by: Michael Walle <michael@walle.cc>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Michael Walle 2022-07-12 15:15:54 +02:00 committed by David S. Miller
parent 1e9aa7baf0
commit d523f2eb1d

View file

@ -230,8 +230,9 @@ static int gpy_probe(struct phy_device *phydev)
return ret;
/* Show GPY PHY FW version in dmesg */
phydev_info(phydev, "Firmware Version: 0x%04X (%s)\n", fw_version,
(fw_version & PHY_FWV_REL_MASK) ? "release" : "test");
phydev_info(phydev, "Firmware Version: %d.%d (0x%04X%s)\n",
priv->fw_major, priv->fw_minor, fw_version,
fw_version & PHY_FWV_REL_MASK ? "" : " test version");
return 0;
}