platform/x86: pmc_atom: Add several Beckhoff Automation boards to critclk_systems DMI table

There are several Beckhoff Automation industrial PC boards which use
pmc_plt_clk* clocks for ethernet controllers. This adds affected boards
to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and
not turned off.

Fixes: 648e921888 ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
This commit is contained in:
Steffen Dirkwinkel 2019-05-02 15:03:51 +02:00 committed by Andy Shevchenko
parent 3d0818f5eb
commit d6423bd030

View file

@ -413,6 +413,30 @@ static const struct dmi_system_id critclk_systems[] = {
DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
},
},
{
/* pmc_plt_clk* - are used for ethernet controllers */
.ident = "Beckhoff CB3163",
.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
},
},
{
/* pmc_plt_clk* - are used for ethernet controllers */
.ident = "Beckhoff CB6263",
.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
},
},
{
/* pmc_plt_clk* - are used for ethernet controllers */
.ident = "Beckhoff CB6363",
.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
},
},
{ /*sentinel*/ }
};