arm64: dts: qcom: ipq8074: drop USB PHY clock index
The QMP USB PHY provides a single clock so drop the redundant clock index. Signed-off-by: Johan Hovold <johan+linaro@kernel.org> Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org> Signed-off-by: Bjorn Andersson <bjorn.andersson@linaro.org> Link: https://lore.kernel.org/r/20220705114032.22787-5-johan+linaro@kernel.org
This commit is contained in:
parent
9215a64a07
commit
de9e7f77d8
1 changed files with 2 additions and 2 deletions
|
@ -130,7 +130,7 @@ usb1_ssphy: phy@58200 {
|
||||||
<0x00058800 0x1f8>, /* PCS */
|
<0x00058800 0x1f8>, /* PCS */
|
||||||
<0x00058600 0x044>; /* PCS misc*/
|
<0x00058600 0x044>; /* PCS misc*/
|
||||||
#phy-cells = <0>;
|
#phy-cells = <0>;
|
||||||
#clock-cells = <1>;
|
#clock-cells = <0>;
|
||||||
clocks = <&gcc GCC_USB1_PIPE_CLK>;
|
clocks = <&gcc GCC_USB1_PIPE_CLK>;
|
||||||
clock-names = "pipe0";
|
clock-names = "pipe0";
|
||||||
clock-output-names = "gcc_usb1_pipe_clk_src";
|
clock-output-names = "gcc_usb1_pipe_clk_src";
|
||||||
|
@ -173,7 +173,7 @@ usb0_ssphy: phy@78200 {
|
||||||
<0x00078800 0x1f8>, /* PCS */
|
<0x00078800 0x1f8>, /* PCS */
|
||||||
<0x00078600 0x044>; /* PCS misc*/
|
<0x00078600 0x044>; /* PCS misc*/
|
||||||
#phy-cells = <0>;
|
#phy-cells = <0>;
|
||||||
#clock-cells = <1>;
|
#clock-cells = <0>;
|
||||||
clocks = <&gcc GCC_USB0_PIPE_CLK>;
|
clocks = <&gcc GCC_USB0_PIPE_CLK>;
|
||||||
clock-names = "pipe0";
|
clock-names = "pipe0";
|
||||||
clock-output-names = "gcc_usb0_pipe_clk_src";
|
clock-output-names = "gcc_usb0_pipe_clk_src";
|
||||||
|
|