platform/x86: pmc_atom: Add Siemens CONNECT X300 to critclk_systems DMI table

The CONNECT X300 uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this
device to the critical systems list.
Tested on CONNECT X300.

Fixes: 648e921888 ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Michael Haener <michael.haener@siemens.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
This commit is contained in:
Michael Haener 2019-11-29 10:16:49 +01:00 committed by Andy Shevchenko
parent 133b2acee3
commit e8796c6c69

View file

@ -429,6 +429,14 @@ static const struct dmi_system_id critclk_systems[] = {
DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"),
},
},
{
.ident = "CONNECT X300",
.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588"),
},
},
{ /*sentinel*/ }
};