ARM: dts: exynos4: Specify PWM clocks in PWM node

Since pwm-samsung bindings require at least one clock to be specified,
this patch adds the missing clocks and clock-names properties to specify
clocks used by PWM block on Exynos4 SoCs.

Signed-off-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
This commit is contained in:
Tomasz Figa 2013-08-26 19:08:57 +02:00 committed by Mike Turquette
parent f51a87a9fb
commit ec06dbe773

View file

@ -342,6 +342,8 @@ pwm@139D0000 {
compatible = "samsung,exynos4210-pwm";
reg = <0x139D0000 0x1000>;
interrupts = <0 37 0>, <0 38 0>, <0 39 0>, <0 40 0>, <0 41 0>;
clocks = <&clock 336>;
clock-names = "timers";
#pwm-cells = <2>;
status = "disabled";
};