platform/x86: pmc_atom: Add Siemens SIMATIC IPC277E to critclk_systems DMI table
The SIMATIC IPC277E uses the PMC clock for on-board components
and gets stuck during boot if the clock is disabled. Therefore,
add this device to the critical systems list.
Tested on SIMATIC IPC277E.
Fixes: 648e921888
("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Reviewed-by: Jan Kiszka <jan.kiszka@siemens.com>
Cc: Cedric Hombourger <Cedric_Hombourger@mentor.com>
Signed-off-by: Srikanth Krishnakar <Srikanth_Krishnakar@mentor.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
This commit is contained in:
parent
b3abfd778b
commit
f110d252ae
1 changed files with 7 additions and 0 deletions
|
@ -422,6 +422,13 @@ static const struct dmi_system_id critclk_systems[] = {
|
|||
DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
|
||||
},
|
||||
},
|
||||
{
|
||||
.ident = "SIMATIC IPC277E",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
|
||||
DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"),
|
||||
},
|
||||
},
|
||||
{ /*sentinel*/ }
|
||||
};
|
||||
|
||||
|
|