serial: max310x: Remove excess port configure at startup

Serial core calls set_termios() after port startup, so there are
no reason to setup port twice.

Signed-off-by: Alexander Shiyan <shc_work@mail.ru>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Alexander Shiyan 2014-02-07 18:16:06 +04:00 committed by Greg Kroah-Hartman
parent 1e6128b635
commit f4fcc40b56

View file

@ -896,12 +896,6 @@ static int max310x_startup(struct uart_port *port)
s->devtype->power(port, 1);
/* Configure baud rate, 9600 as default */
max310x_set_baud(port, 9600);
/* Configure LCR register, 8N1 mode by default */
max310x_port_write(port, MAX310X_LCR_REG, MAX310X_LCR_WORD_LEN_8);
/* Configure MODE1 register */
max310x_port_update(port, MAX310X_MODE1_REG,
MAX310X_MODE1_TRNSCVCTRL_BIT,