net: phy: lan87xx: fix access to wrong register of LAN87xx

The function lan87xx_config_aneg_ext was introduced to configure
LAN95xxA but as well writes to undocumented register of LAN87xx.
This fix prevents that access.

The function lan87xx_config_aneg_ext gets more suitable for the new
behavior name.

Reported-by: Måns Rullgård <mans@mansr.com>
Fixes: 05b35e7eb9 ("smsc95xx: add phylib support")
Signed-off-by: Andre Edich <andre.edich@microchip.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Andre Edich 2021-03-29 11:45:36 +02:00 committed by David S. Miller
parent 9c0ee085c4
commit fdb5cc6ab3

View file

@ -185,10 +185,13 @@ static int lan87xx_config_aneg(struct phy_device *phydev)
return genphy_config_aneg(phydev);
}
static int lan87xx_config_aneg_ext(struct phy_device *phydev)
static int lan95xx_config_aneg_ext(struct phy_device *phydev)
{
int rc;
if (phydev->phy_id != 0x0007c0f0) /* not (LAN9500A or LAN9505A) */
return lan87xx_config_aneg(phydev);
/* Extend Manual AutoMDIX timer */
rc = phy_read(phydev, PHY_EDPD_CONFIG);
if (rc < 0)
@ -441,7 +444,7 @@ static struct phy_driver smsc_phy_driver[] = {
.read_status = lan87xx_read_status,
.config_init = smsc_phy_config_init,
.soft_reset = smsc_phy_reset,
.config_aneg = lan87xx_config_aneg_ext,
.config_aneg = lan95xx_config_aneg_ext,
/* IRQ related */
.config_intr = smsc_phy_config_intr,