Commit Graph

6 Commits

Author SHA1 Message Date
Xuchun Shang b5e3929475 iommu/vt-d: Fix wrong use of pasid config
[ Upstream commit 5b3625a4f6 ]

The commit "iommu/vt-d: Add IOMMU perfmon support" introduce IOMMU
PMU feature, but use the wrong config when set pasid filter.

Fixes: 7232ab8b89 ("iommu/vt-d: Add IOMMU perfmon support")
Signed-off-by: Xuchun Shang <xuchun.shang@linux.alibaba.com>
Reviewed-by: Kan Liang <kan.liang@linux.intel.com>
Link: https://lore.kernel.org/r/20240401060753.3321318-1-xuchun.shang@linux.alibaba.com
Signed-off-by: Lu Baolu <baolu.lu@linux.intel.com>
Signed-off-by: Joerg Roedel <jroedel@suse.de>
Signed-off-by: Sasha Levin <sashal@kernel.org>
2024-04-17 11:23:35 +02:00
Kan Liang 16812c9655 iommu/vt-d: Fix an IOMMU perfmon warning when CPU hotplug
A warning can be triggered when hotplug CPU 0.
$ echo 0 > /sys/devices/system/cpu/cpu0/online

 ------------[ cut here ]------------
 Voluntary context switch within RCU read-side critical section!
 WARNING: CPU: 0 PID: 19 at kernel/rcu/tree_plugin.h:318
          rcu_note_context_switch+0x4f4/0x580
 RIP: 0010:rcu_note_context_switch+0x4f4/0x580
 Call Trace:
  <TASK>
  ? perf_event_update_userpage+0x104/0x150
  __schedule+0x8d/0x960
  ? perf_event_set_state.part.82+0x11/0x50
  schedule+0x44/0xb0
  schedule_timeout+0x226/0x310
  ? __perf_event_disable+0x64/0x1a0
  ? _raw_spin_unlock+0x14/0x30
  wait_for_completion+0x94/0x130
  __wait_rcu_gp+0x108/0x130
  synchronize_rcu+0x67/0x70
  ? invoke_rcu_core+0xb0/0xb0
  ? __bpf_trace_rcu_stall_warning+0x10/0x10
  perf_pmu_migrate_context+0x121/0x370
  iommu_pmu_cpu_offline+0x6a/0xa0
  ? iommu_pmu_del+0x1e0/0x1e0
  cpuhp_invoke_callback+0x129/0x510
  cpuhp_thread_fun+0x94/0x150
  smpboot_thread_fn+0x183/0x220
  ? sort_range+0x20/0x20
  kthread+0xe6/0x110
  ? kthread_complete_and_exit+0x20/0x20
  ret_from_fork+0x1f/0x30
  </TASK>
 ---[ end trace 0000000000000000 ]---

The synchronize_rcu() will be invoked in the perf_pmu_migrate_context(),
when migrating a PMU to a new CPU. However, the current for_each_iommu()
is within RCU read-side critical section.

Two methods were considered to fix the issue.
- Use the dmar_global_lock to replace the RCU read lock when going
  through the drhd list. But it triggers a lockdep warning.
- Use the cpuhp_setup_state_multi() to set up a dedicated state for each
  IOMMU PMU. The lock can be avoided.

The latter method is implemented in this patch. Since each IOMMU PMU has
a dedicated state, add cpuhp_node and cpu in struct iommu_pmu to track
the state. The state can be dynamically allocated now. Remove the
CPUHP_AP_PERF_X86_IOMMU_PERF_ONLINE.

Fixes: 46284c6ceb ("iommu/vt-d: Support cpumask for IOMMU perfmon")
Reported-by: Ammy Yi <ammy.yi@intel.com>
Signed-off-by: Kan Liang <kan.liang@linux.intel.com>
Link: https://lore.kernel.org/r/20230328182028.1366416-1-kan.liang@linux.intel.com
Signed-off-by: Lu Baolu <baolu.lu@linux.intel.com>
Link: https://lore.kernel.org/r/20230329134721.469447-4-baolu.lu@linux.intel.com
Signed-off-by: Joerg Roedel <jroedel@suse.de>
2023-03-31 10:06:16 +02:00
Kan Liang 4a0d426565 iommu/vt-d: Add IOMMU perfmon overflow handler support
While enabled to count events and an event occurrence causes the counter
value to increment and roll over to or past zero, this is termed a
counter overflow. The overflow can trigger an interrupt. The IOMMU
perfmon needs to handle the case properly.

New HW IRQs are allocated for each IOMMU device for perfmon. The IRQ IDs
are after the SVM range.

In the overflow handler, the counter is not frozen. It's very unlikely
that the same counter overflows again during the period. But it's
possible that other counters overflow at the same time. Read the
overflow register at the end of the handler and check whether there are
more.

Signed-off-by: Kan Liang <kan.liang@linux.intel.com>
Link: https://lore.kernel.org/r/20230128200428.1459118-7-kan.liang@linux.intel.com
Signed-off-by: Lu Baolu <baolu.lu@linux.intel.com>
Signed-off-by: Joerg Roedel <jroedel@suse.de>
2023-02-03 11:06:08 +01:00
Kan Liang 46284c6ceb iommu/vt-d: Support cpumask for IOMMU perfmon
The perf subsystem assumes that all counters are by default per-CPU. So
the user space tool reads a counter from each CPU. However, the IOMMU
counters are system-wide and can be read from any CPU. Here we use a CPU
mask to restrict counting to one CPU to handle the issue. (with CPU
hotplug notifier to choose a different CPU if the chosen one is taken
off-line).

The CPU is exposed to /sys/bus/event_source/devices/dmar*/cpumask for
the user space perf tool.

Signed-off-by: Kan Liang <kan.liang@linux.intel.com>
Link: https://lore.kernel.org/r/20230128200428.1459118-6-kan.liang@linux.intel.com
Signed-off-by: Lu Baolu <baolu.lu@linux.intel.com>
Signed-off-by: Joerg Roedel <jroedel@suse.de>
2023-02-03 11:06:08 +01:00
Kan Liang 7232ab8b89 iommu/vt-d: Add IOMMU perfmon support
Implement the IOMMU performance monitor capability, which supports the
collection of information about key events occurring during operation of
the remapping hardware, to aid performance tuning and debug.

The IOMMU perfmon support is implemented as part of the IOMMU driver and
interfaces with the Linux perf subsystem.

The IOMMU PMU has the following unique features compared with the other
PMUs.
- Support counting. Not support sampling.
- Does not support per-thread counting. The scope is system-wide.
- Support per-counter capability register. The event constraints can be
  enumerated.
- The available event and event group can also be enumerated.
- Extra Enhanced Commands are introduced to control the counters.

Add a new variable, struct iommu_pmu *pmu, to in the struct intel_iommu
to track the PMU related information.

Add iommu_pmu_register() and iommu_pmu_unregister() to register and
unregister a IOMMU PMU. The register function setup the IOMMU PMU ops
and invoke the standard perf_pmu_register() interface to register a PMU
in the perf subsystem. This patch only exposes the functions. The
following patch will enable them in the IOMMU driver.

The IOMMU PMUs can be found under /sys/bus/event_source/devices/dmar*

The available filters and event format can be found at the format folder

 $ ls /sys/bus/event_source/devices/dmar1/format/
 event  event_group  filter_ats  filter_ats_en  filter_page_table
 filter_page_table_en

The supported events can be found at the events folder

 $ ls /sys/bus/event_source/devices/dmar1/events/
 ats_blocked        fs_nonleaf_hit           int_cache_hit_posted
 iommu_mem_blocked  iotlb_hit        pasid_cache_lookup  ss_nonleaf_hit
 ctxt_cache_hit     fs_nonleaf_lookup        int_cache_lookup
 iommu_mrds         iotlb_lookup     pg_req_posted    ss_nonleaf_lookup
 ctxt_cache_lookup  int_cache_hit_nonposted  iommu_clocks
 iommu_requests     pasid_cache_hit  pw_occupancy

The command below illustrates filter usage with a simple example.

 $ perf stat -e dmar1/iommu_requests,filter_ats_en=0x1,filter_ats=0x1/
   -a sleep 1

 Performance counter stats for 'system wide':

   368,947      dmar1/iommu_requests,filter_ats_en=0x1,filter_ats=0x1/

 1.002592074 seconds time elapsed

Signed-off-by: Kan Liang <kan.liang@linux.intel.com>
Link: https://lore.kernel.org/r/20230128200428.1459118-5-kan.liang@linux.intel.com
Signed-off-by: Lu Baolu <baolu.lu@linux.intel.com>
Signed-off-by: Joerg Roedel <jroedel@suse.de>
2023-02-03 11:06:06 +01:00
Kan Liang a6a5006dad iommu/vt-d: Retrieve IOMMU perfmon capability information
The performance monitoring infrastructure, perfmon, is to support
collection of information about key events occurring during operation of
the remapping hardware, to aid performance tuning and debug. Each
remapping hardware unit has capability registers that indicate support
for performance monitoring features and enumerate the capabilities.

Add alloc_iommu_pmu() to retrieve IOMMU perfmon capability information
for each iommu unit. The information is stored in the iommu->pmu data
structure. Capability registers are read-only, so it's safe to prefetch
and store them in the pmu structure. This could avoid unnecessary VMEXIT
when this code is running in the virtualization environment.

Add free_iommu_pmu() to free the saved capability information when
freeing the iommu unit.

Add a kernel config option for the IOMMU perfmon feature. Unless a user
explicitly uses the perf tool to monitor the IOMMU perfmon event, there
isn't any impact for the existing IOMMU. Enable it by default.

Signed-off-by: Kan Liang <kan.liang@linux.intel.com>
Link: https://lore.kernel.org/r/20230128200428.1459118-3-kan.liang@linux.intel.com
Signed-off-by: Lu Baolu <baolu.lu@linux.intel.com>
Signed-off-by: Joerg Roedel <jroedel@suse.de>
2023-02-03 11:06:04 +01:00