Commit graph

2 commits

Author SHA1 Message Date
lan,Tianyu
ced2284339 Thermal/int3403: Fix thermal hysteresis unit conversion
Thermal hysteresis represents a temperature difference.
But the original code treats it as a temperature value,
Convert it from tenths of degree Kelvin to Milli-Celsius
by deducing 273200. This is not right.

Kelvin and Celsius have same degree size. From temperature
difference view, the conversion between tenths of degree
Kelvin unit and Milli-Celsius unit is just to multiply 100.

Signed-off-by: Lan Tianyu <tianyu.lan@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-05-15 16:38:48 +08:00
Srinivas Pandruvada
925c36bb09 Thermal: ACPI INT3403 thermal driver
The ACPI INT3403 device objects present on some systems can be used to retrieve
temperature data from thermal sensors. Add a driver registering each INT3403
device object as a thermal zone device and exposing its _TMP, PATx and GTSH
method via the standard thermal control interface under /sys/class/thermal/.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-01-02 09:42:12 +08:00