Setting polling_delay is now done at thermal_core level (by not polling
DISABLED devices), so no need to repeat this code.
int340x: Checking for an impossible enum value is unnecessary.
acpi/thermal: It only prints debug messages.
Signed-off-by: Andrzej Pietrasiewicz <andrzej.p@collabora.com>
[for acerhdf]
Acked-by: Peter Kaestle <peter@piie.net>
Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>
Reviewed-by: Amit Kucheria <amit.kucheria@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200629122925.21729-11-andrzej.p@collabora.com
Use thermal_zone_device_{en|dis}able() and thermal_zone_device_is_enabled().
Consequently, all set_mode() implementations in drivers:
- can stop modifying tzd's "mode" member,
- shall stop taking tzd's lock, as it is taken in the helpers
- shall stop calling thermal_zone_device_update() as it is called in the
helpers
- can assume they are called when the mode truly changes, so checks to
verify that can be dropped
Not providing set_mode() by a driver no longer prevents the core from
being able to set tzd's mode, so the relevant check in mode_store() is
removed.
Other comments:
- acpi/thermal.c: tz->thermal_zone->mode will be updated only after we
return from set_mode(), so use function parameter in thermal_set_mode()
instead, no need to call acpi_thermal_check() in set_mode()
- thermal/imx_thermal.c: regmap writes and mode assignment are done in
thermal_zone_device_{en|dis}able() and set_mode() callback
- thermal/intel/intel_quark_dts_thermal.c: soc_dts_{en|dis}able() are a
part of set_mode() callback, so they don't need to modify tzd->mode, and
don't need to fall back to the opposite mode if unsuccessful, as the return
value will be propagated to thermal_zone_device_{en|dis}able() and
ultimately tzd's member will not be changed in thermal_zone_device_set_mode().
- thermal/of-thermal.c: no need to set zone->mode to DISABLED in
of_parse_thermal_zones() as a tzd is kzalloc'ed so mode is DISABLED anyway
Signed-off-by: Andrzej Pietrasiewicz <andrzej.p@collabora.com>
[for acerhdf]
Acked-by: Peter Kaestle <peter@piie.net>
Reviewed-by: Amit Kucheria <amit.kucheria@linaro.org>
Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200629122925.21729-8-andrzej.p@collabora.com
get_mode() is now redundant, as the state is stored in struct
thermal_zone_device.
Consequently the "mode" attribute in sysfs can always be visible, because
it is always possible to get the mode from struct tzd.
Signed-off-by: Andrzej Pietrasiewicz <andrzej.p@collabora.com>
[for acerhdf]
Acked-by: Peter Kaestle <peter@piie.net>
Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>
Reviewed-by: Amit Kucheria <amit.kucheria@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200629122925.21729-6-andrzej.p@collabora.com