linux-stable/drivers/iio/common
Javier Carrasco 54cf39ec16 iio: common: ms_sensors: ms_sensors_i2c: fix humidity conversion time table
The HTU21 offers 4 sampling frequencies: 20, 40, 70 and 120, which are
associated to an index that is used to select the right measurement
resolution and its corresponding measurement time. The current
implementation selects the measurement resolution and the temperature
measurement time properly, but it does not select the right humidity
measurement time in all cases.

In summary, the 40 and 70 humidity measurement times are swapped.

The reason for that is probably the unusual coding for the measurement
resolution. According to the datasheet, the bits [7,0] of the "user
register" are used as follows to select the bit resolution:

--------------------------------------------------
| Bit 7 | Bit 0 | RH | Temp | Trh (us) | Tt (us) |
--------------------------------------------------
|   0   |   0   | 12 |  14  |  16000   |  50000  |
--------------------------------------------------
|   0   |   1   | 8  |  12  |  3000    |  13000  |
--------------------------------------------------
|   1   |   0   | 10 |  13  |  5000    |  25000  |
--------------------------------------------------
|   1   |   1   | 11 |  11  |  8000    |  7000   |
--------------------------------------------------
*This table is available in the official datasheet, page 13/21. I have
just appended the times provided in the humidity/temperature tables,
pages 3/21, 5/21. Note that always a pair of resolutions is selected.

The sampling frequencies [20, 40, 70, 120] are assigned to a linear
index [0..3] which is then coded as follows [1]:

Index    [7,0]
--------------
idx 0     0,0
idx 1     1,0
idx 2     0,1
idx 3     1,1

That is done that way because the temperature measurements are being
used as the reference for the sampling frequency (the frequencies and
the temperature measurement times are correlated), so increasing the
index always reduces the temperature measurement time and its
resolution. Therefore, the temperature measurement time array is as
simple as [50000, 25000, 13000, 7000]

On the other hand, the humidity resolution cannot follow the same
pattern because of the way it is coded in the "user register", where
both resolutions are selected at the same time. The humidity measurement
time array is the following: [16000, 3000, 5000, 8000], which defines
the following assignments:

Index    [7,0]    Trh
-----------------------
idx 0     0,0     16000  -> right, [0,0] selects 12 bits (Trh = 16000)
idx 1     1,0     3000   -> wrong! [1,0] selects 10 bits (Trh = 5000)
idx 2     0,1     5000   -> wrong! [0,1] selects 8 bits (Trh = 3000)
idx 3     1,1     8000   -> right, [1,1] selects 11 bits (Trh = 8000)

The times have been ordered as if idx = 1 -> [0,1] and idx = 2 -> [1,0],
which is not the case for the reason explained above.

So a simple modification is required to obtain the right humidity
measurement time array, swapping the values in the positions 1 and 2.

The right table should be the following: [16000, 5000, 3000, 8000]

Fix the humidity measurement time array with the right idex/value
coding.

[1] The actual code that makes this coding and assigns it to the current
value of the "user register" is the following:
config_reg &= 0x7E;
config_reg |= ((i & 1) << 7) + ((i & 2) >> 1);

Fixes: d574a87cc3 ("Add meas-spec sensors common part")
Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com>
Link: https://lore.kernel.org/r/20231026-topic-htu21_conversion_time-v1-1-bd257dc44209@gmail.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2023-11-16 19:35:41 +00:00
..
cros_ec_sensors iio: cros_ec: fix an use-after-free in cros_ec_sensors_push_data() 2023-10-05 18:06:45 +01:00
hid-sensors iio: Don't silently expect attribute types 2022-11-23 19:44:04 +00:00
inv_sensors iio: make invensense timestamp module generic 2023-07-20 19:21:28 +01:00
ms_sensors iio: common: ms_sensors: ms_sensors_i2c: fix humidity conversion time table 2023-11-16 19:35:41 +00:00
scmi_sensors iio: common: scmi_iio: use sysfs_emit() to instead of scnprintf() 2022-12-28 17:19:45 +00:00
ssp_sensors iio: common: ssp: Fix alignment for DMA safety 2022-06-14 11:53:15 +01:00
st_sensors iio: Rename iio_trigger_poll_chained and add kernel-doc 2023-03-11 12:18:29 +00:00
Kconfig iio: move inv_icm42600 timestamp module in common 2023-07-20 19:21:28 +01:00
Makefile iio: move inv_icm42600 timestamp module in common 2023-07-20 19:21:28 +01:00