.. SPDX-License-Identifier: GPL-2.0
Kernel driver drivetemp
=======================
References
----------
ANS T13/1699-D
Information technology - AT Attachment 8 - ATA/ATAPI Command Set (ATA8-ACS)
ANS Project T10/BSR INCITS 513
Information technology - SCSI Primary Commands - 4 (SPC-4)
ANS Project INCITS 557
Information technology - SCSI / ATA Translation - 5 (SAT-5)
Description
-----------
This driver supports reporting the temperature of disk and solid state
drives with temperature sensors.
If supported, it uses the ATA SCT Command Transport feature to read
the current drive temperature and, if available, temperature limits
as well as historic minimum and maximum temperatures. If SCT Command
Transport is not supported, the driver uses SMART attributes to read
the drive temperature.
Usage Note
----------
Reading the drive temperature may reset the spin down timer on some drives.
This has been observed with WD120EFAX drives, but may be seen with other
drives as well. The same behavior is observed if the 'hdtemp' or 'smartd'
tools are used to access the drive.
With the WD120EFAX drive, reading the drive temperature using the drivetemp
driver is still possible _after_ it transitioned to standby mode, and
reading the drive temperature in this mode will not cause the drive to
change its mode (meaning the drive will not spin up). It is unknown if other
drives experience similar behavior.
A known workaround for WD120EFAX drives is to read the drive temperature at
intervals larger than twice the spin-down time. Otherwise affected drives
will never spin down.
Sysfs entries
-------------
Only the temp1_input attribute is always available. Other attributes are
available only if reported by the drive. All temperatures are reported in
milli-degrees Celsius.
======================= =====================================================
temp1_input Current drive temperature
temp1_lcrit Minimum temperature limit. Operating the device below
this temperature may cause physical damage to the
device.
temp1_min Minimum recommended continuous operating limit
temp1_max Maximum recommended continuous operating temperature
temp1_crit Maximum temperature limit. Operating the device above
this temperature may cause physical damage to the
device.
temp1_lowest Minimum temperature seen this power cycle
temp1_highest Maximum temperature seen this power cycle
======================= =====================================================