In some cases when the platform is dissapating more than 500mA the voltage measurements and compensation will become instable. Add a parameter to bail out of the voltage measurement if this happens. This code was found in a Samsung vendor tree. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com> |
||
---|---|---|
.. | ||