Commit e504c9098e (kvm, vmx: Fix lazy FPU on nested guest, 2013-11-13)
highlighted a real problem, but the fix was subtly wrong.
nested_read_cr0 is the CR0 as read by L2, but here we want to look at
the CR0 value reflecting L1's setup. In other words, L2 might think
that TS=0 (so nested_read_cr0 has the bit clear); but if L1 is actually
running it with TS=1, we should inject the fault into L1.
The effective value of CR0 in L2 is contained in vmcs12->guest_cr0, use
it.
Fixes: e504c9098e
Reported-by: Kashyap Chamarty <kchamart@redhat.com>
Reported-by: Stefan Bader <stefan.bader@canonical.com>
Tested-by: Kashyap Chamarty <kchamart@redhat.com>
Tested-by: Anthoine Bourgeois <bourgeois@bertin.fr>
Cc: stable@vger.kernel.org
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>