mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git
synced 2024-09-15 15:15:47 +00:00
e8245c6835
The ADS1015 device have two operating modes, continuous conversion mode and single-shot mode. This driver assumes that the continuous conversion mode is selected by runtime resume callback when the ADC result is requested. If CONFIG_PM is disabled, the device is always in the default single-shot mode and no one begins a single conversion. So the conversion register doesn't contain valid ADC result. Fix it by changing the continuous mode in probe function. Cc: Daniel Baluta <daniel.baluta@gmail.com> Signed-off-by: Akinobu Mita <akinobu.mita@gmail.com> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> |
||
---|---|---|
.. | ||