linux-stable/drivers/thermal/cpu_cooling.c
Viresh Kumar f6859014c7 thermal: cpu_cooling: Store frequencies in descending order
CPUFreq framework *doesn't* guarantee that frequencies present in cpufreq table
will be in ascending or descending order. But cpu_cooling somehow assumes that.

Probably because most of current users are creating this list from DT, which is
done with the help of OPP layer. And OPP layer creates the list in ascending
order of frequencies.

But cpu_cooling can be used for other platforms too, which don't have
frequencies arranged in any order.

This patch tries to fix this issue by creating another list of valid frequencies
in descending order. Care is also taken to throw warnings for duplicate entries.

Later patches would use it to simplify code.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:11:02 -04:00

549 lines
16 KiB
C

/*
* linux/drivers/thermal/cpu_cooling.c
*
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
* Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org>
*
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; version 2 of the License.
*
* This program is distributed in the hope that it will be useful, but
* WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
* General Public License for more details.
*
* You should have received a copy of the GNU General Public License along
* with this program; if not, write to the Free Software Foundation, Inc.,
* 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
*
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
*/
#include <linux/module.h>
#include <linux/thermal.h>
#include <linux/cpufreq.h>
#include <linux/err.h>
#include <linux/slab.h>
#include <linux/cpu.h>
#include <linux/cpu_cooling.h>
/*
* Cooling state <-> CPUFreq frequency
*
* Cooling states are translated to frequencies throughout this driver and this
* is the relation between them.
*
* Highest cooling state corresponds to lowest possible frequency.
*
* i.e.
* level 0 --> 1st Max Freq
* level 1 --> 2nd Max Freq
* ...
*/
/**
* struct cpufreq_cooling_device - data for cooling device with cpufreq
* @id: unique integer value corresponding to each cpufreq_cooling_device
* registered.
* @cool_dev: thermal_cooling_device pointer to keep track of the
* registered cooling device.
* @cpufreq_state: integer value representing the current state of cpufreq
* cooling devices.
* @cpufreq_val: integer value representing the absolute value of the clipped
* frequency.
* @max_level: maximum cooling level. One less than total number of valid
* cpufreq frequencies.
* @allowed_cpus: all the cpus involved for this cpufreq_cooling_device.
*
* This structure is required for keeping information of each registered
* cpufreq_cooling_device.
*/
struct cpufreq_cooling_device {
int id;
struct thermal_cooling_device *cool_dev;
unsigned int cpufreq_state;
unsigned int cpufreq_val;
unsigned int max_level;
unsigned int *freq_table; /* In descending order */
struct cpumask allowed_cpus;
struct list_head node;
};
static DEFINE_IDR(cpufreq_idr);
static DEFINE_MUTEX(cooling_cpufreq_lock);
static LIST_HEAD(cpufreq_dev_list);
/**
* get_idr - function to get a unique id.
* @idr: struct idr * handle used to create a id.
* @id: int * value generated by this function.
*
* This function will populate @id with an unique
* id, using the idr API.
*
* Return: 0 on success, an error code on failure.
*/
static int get_idr(struct idr *idr, int *id)
{
int ret;
mutex_lock(&cooling_cpufreq_lock);
ret = idr_alloc(idr, NULL, 0, 0, GFP_KERNEL);
mutex_unlock(&cooling_cpufreq_lock);
if (unlikely(ret < 0))
return ret;
*id = ret;
return 0;
}
/**
* release_idr - function to free the unique id.
* @idr: struct idr * handle used for creating the id.
* @id: int value representing the unique id.
*/
static void release_idr(struct idr *idr, int id)
{
mutex_lock(&cooling_cpufreq_lock);
idr_remove(idr, id);
mutex_unlock(&cooling_cpufreq_lock);
}
/* Below code defines functions to be used for cpufreq as cooling device */
enum cpufreq_cooling_property {
GET_LEVEL,
GET_FREQ,
};
/**
* get_property - fetch a property of interest for a given cpu.
* @cpufreq_dev: cpufreq_dev for which the property is required
* @input: query parameter
* @output: query return
* @property: type of query (frequency, level)
*
* This is the common function to
* 1. translate frequency to cooling state
* 2. translate cooling state to frequency
*
* Note that the code may be not in good shape
* but it is written in this way in order to:
* a) reduce duplicate code as most of the code can be shared.
* b) make sure the logic is consistent when translating between
* cooling states and frequencies.
*
* Return: 0 on success, -EINVAL when invalid parameters are passed.
*/
static int get_property(struct cpufreq_cooling_device *cpufreq_dev,
unsigned long input, unsigned int *output,
enum cpufreq_cooling_property property)
{
int i;
unsigned long level = 0;
unsigned int freq = CPUFREQ_ENTRY_INVALID;
int descend = -1;
struct cpufreq_frequency_table *pos, *table;
if (!output)
return -EINVAL;
table = cpufreq_frequency_get_table(cpumask_first(&cpufreq_dev->allowed_cpus));
if (!table)
return -EINVAL;
cpufreq_for_each_valid_entry(pos, table) {
/* ignore duplicate entry */
if (freq == pos->frequency)
continue;
/* get the frequency order */
if (freq != CPUFREQ_ENTRY_INVALID && descend == -1)
descend = freq > pos->frequency;
freq = pos->frequency;
}
if (property == GET_FREQ)
level = descend ? input : (cpufreq_dev->max_level - input);
i = 0;
cpufreq_for_each_valid_entry(pos, table) {
/* ignore duplicate entry */
if (freq == pos->frequency)
continue;
/* now we have a valid frequency entry */
freq = pos->frequency;
if (property == GET_LEVEL && (unsigned int)input == freq) {
/* get level by frequency */
*output = descend ? i : (cpufreq_dev->max_level - i);
return 0;
}
if (property == GET_FREQ && level == i) {
/* get frequency by level */
*output = freq;
return 0;
}
i++;
}
return -EINVAL;
}
/**
* cpufreq_cooling_get_level - for a given cpu, return the cooling level.
* @cpu: cpu for which the level is required
* @freq: the frequency of interest
*
* This function will match the cooling level corresponding to the
* requested @freq and return it.
*
* Return: The matched cooling level on success or THERMAL_CSTATE_INVALID
* otherwise.
*/
unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
{
struct cpufreq_cooling_device *cpufreq_dev;
mutex_lock(&cooling_cpufreq_lock);
list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) {
unsigned int val;
mutex_unlock(&cooling_cpufreq_lock);
if (get_property(cpufreq_dev, (unsigned long)freq, &val,
GET_LEVEL))
return THERMAL_CSTATE_INVALID;
return (unsigned long)val;
}
}
mutex_unlock(&cooling_cpufreq_lock);
pr_err("%s: cpu:%d not part of any cooling device\n", __func__, cpu);
return THERMAL_CSTATE_INVALID;
}
EXPORT_SYMBOL_GPL(cpufreq_cooling_get_level);
/**
* cpufreq_thermal_notifier - notifier callback for cpufreq policy change.
* @nb: struct notifier_block * with callback info.
* @event: value showing cpufreq event for which this function invoked.
* @data: callback-specific data
*
* Callback to hijack the notification on cpufreq policy transition.
* Every time there is a change in policy, we will intercept and
* update the cpufreq policy with thermal constraints.
*
* Return: 0 (success)
*/
static int cpufreq_thermal_notifier(struct notifier_block *nb,
unsigned long event, void *data)
{
struct cpufreq_policy *policy = data;
unsigned long max_freq = 0;
struct cpufreq_cooling_device *cpufreq_dev;
if (event != CPUFREQ_ADJUST)
return 0;
mutex_lock(&cooling_cpufreq_lock);
list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
if (!cpumask_test_cpu(policy->cpu,
&cpufreq_dev->allowed_cpus))
continue;
max_freq = cpufreq_dev->cpufreq_val;
if (policy->max != max_freq)
cpufreq_verify_within_limits(policy, 0, max_freq);
}
mutex_unlock(&cooling_cpufreq_lock);
return 0;
}
/* cpufreq cooling device callback functions are defined below */
/**
* cpufreq_get_max_state - callback function to get the max cooling state.
* @cdev: thermal cooling device pointer.
* @state: fill this variable with the max cooling state.
*
* Callback for the thermal cooling device to return the cpufreq
* max cooling state.
*
* Return: 0 on success, an error code otherwise.
*/
static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
unsigned long *state)
{
struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
*state = cpufreq_device->max_level;
return 0;
}
/**
* cpufreq_get_cur_state - callback function to get the current cooling state.
* @cdev: thermal cooling device pointer.
* @state: fill this variable with the current cooling state.
*
* Callback for the thermal cooling device to return the cpufreq
* current cooling state.
*
* Return: 0 on success, an error code otherwise.
*/
static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
unsigned long *state)
{
struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
*state = cpufreq_device->cpufreq_state;
return 0;
}
/**
* cpufreq_set_cur_state - callback function to set the current cooling state.
* @cdev: thermal cooling device pointer.
* @state: set this variable to the current cooling state.
*
* Callback for the thermal cooling device to change the cpufreq
* current cooling state.
*
* Return: 0 on success, an error code otherwise.
*/
static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
unsigned long state)
{
struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
unsigned int cpu = cpumask_any(&cpufreq_device->allowed_cpus);
unsigned int clip_freq;
int ret;
/* Check if the old cooling action is same as new cooling action */
if (cpufreq_device->cpufreq_state == state)
return 0;
ret = get_property(cpufreq_device, state, &clip_freq, GET_FREQ);
if (ret)
return ret;
cpufreq_device->cpufreq_state = state;
cpufreq_device->cpufreq_val = clip_freq;
cpufreq_update_policy(cpu);
return 0;
}
/* Bind cpufreq callbacks to thermal cooling device ops */
static struct thermal_cooling_device_ops const cpufreq_cooling_ops = {
.get_max_state = cpufreq_get_max_state,
.get_cur_state = cpufreq_get_cur_state,
.set_cur_state = cpufreq_set_cur_state,
};
/* Notifier for cpufreq policy change */
static struct notifier_block thermal_cpufreq_notifier_block = {
.notifier_call = cpufreq_thermal_notifier,
};
static unsigned int find_next_max(struct cpufreq_frequency_table *table,
unsigned int prev_max)
{
struct cpufreq_frequency_table *pos;
unsigned int max = 0;
cpufreq_for_each_valid_entry(pos, table) {
if (pos->frequency > max && pos->frequency < prev_max)
max = pos->frequency;
}
return max;
}
/**
* __cpufreq_cooling_register - helper function to create cpufreq cooling device
* @np: a valid struct device_node to the cooling device device tree node
* @clip_cpus: cpumask of cpus where the frequency constraints will happen.
* Normally this should be same as cpufreq policy->related_cpus.
*
* This interface function registers the cpufreq cooling device with the name
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
* cooling devices. It also gives the opportunity to link the cooling device
* with a device tree node, in order to bind it via the thermal DT code.
*
* Return: a valid struct thermal_cooling_device pointer on success,
* on failure, it returns a corresponding ERR_PTR().
*/
static struct thermal_cooling_device *
__cpufreq_cooling_register(struct device_node *np,
const struct cpumask *clip_cpus)
{
struct thermal_cooling_device *cool_dev;
struct cpufreq_cooling_device *cpufreq_dev;
char dev_name[THERMAL_NAME_LENGTH];
struct cpufreq_frequency_table *pos, *table;
unsigned int freq, i;
int ret;
table = cpufreq_frequency_get_table(cpumask_first(clip_cpus));
if (!table) {
pr_debug("%s: CPUFreq table not found\n", __func__);
return ERR_PTR(-EPROBE_DEFER);
}
cpufreq_dev = kzalloc(sizeof(*cpufreq_dev), GFP_KERNEL);
if (!cpufreq_dev)
return ERR_PTR(-ENOMEM);
ret = get_property(cpufreq_dev, 0, &cpufreq_dev->cpufreq_val, GET_FREQ);
if (ret) {
pr_err("%s: Failed to get frequency: %d", __func__, ret);
cool_dev = ERR_PTR(ret);
goto free_cdev;
}
/* Find max levels */
cpufreq_for_each_valid_entry(pos, table)
cpufreq_dev->max_level++;
cpufreq_dev->freq_table = kmalloc(sizeof(*cpufreq_dev->freq_table) *
cpufreq_dev->max_level, GFP_KERNEL);
if (!cpufreq_dev->freq_table) {
return ERR_PTR(-ENOMEM);
cool_dev = ERR_PTR(-ENOMEM);
goto free_cdev;
}
/* max_level is an index, not a counter */
cpufreq_dev->max_level--;
cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus);
ret = get_idr(&cpufreq_idr, &cpufreq_dev->id);
if (ret) {
cool_dev = ERR_PTR(ret);
goto free_table;
}
snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
cpufreq_dev->id);
cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
&cpufreq_cooling_ops);
if (IS_ERR(cool_dev))
goto remove_idr;
/* Fill freq-table in descending order of frequencies */
for (i = 0, freq = -1; i <= cpufreq_dev->max_level; i++) {
freq = find_next_max(table, freq);
cpufreq_dev->freq_table[i] = freq;
/* Warn for duplicate entries */
if (!freq)
pr_warn("%s: table has duplicate entries\n", __func__);
else
pr_debug("%s: freq:%u KHz\n", __func__, freq);
}
cpufreq_dev->cool_dev = cool_dev;
mutex_lock(&cooling_cpufreq_lock);
/* Register the notifier for first cpufreq cooling device */
if (list_empty(&cpufreq_dev_list))
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);
list_add(&cpufreq_dev->node, &cpufreq_dev_list);
mutex_unlock(&cooling_cpufreq_lock);
return cool_dev;
remove_idr:
release_idr(&cpufreq_idr, cpufreq_dev->id);
free_table:
kfree(cpufreq_dev->freq_table);
free_cdev:
kfree(cpufreq_dev);
return cool_dev;
}
/**
* cpufreq_cooling_register - function to create cpufreq cooling device.
* @clip_cpus: cpumask of cpus where the frequency constraints will happen.
*
* This interface function registers the cpufreq cooling device with the name
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
* cooling devices.
*
* Return: a valid struct thermal_cooling_device pointer on success,
* on failure, it returns a corresponding ERR_PTR().
*/
struct thermal_cooling_device *
cpufreq_cooling_register(const struct cpumask *clip_cpus)
{
return __cpufreq_cooling_register(NULL, clip_cpus);
}
EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
/**
* of_cpufreq_cooling_register - function to create cpufreq cooling device.
* @np: a valid struct device_node to the cooling device device tree node
* @clip_cpus: cpumask of cpus where the frequency constraints will happen.
*
* This interface function registers the cpufreq cooling device with the name
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
* cooling devices. Using this API, the cpufreq cooling device will be
* linked to the device tree node provided.
*
* Return: a valid struct thermal_cooling_device pointer on success,
* on failure, it returns a corresponding ERR_PTR().
*/
struct thermal_cooling_device *
of_cpufreq_cooling_register(struct device_node *np,
const struct cpumask *clip_cpus)
{
if (!np)
return ERR_PTR(-EINVAL);
return __cpufreq_cooling_register(np, clip_cpus);
}
EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
/**
* cpufreq_cooling_unregister - function to remove cpufreq cooling device.
* @cdev: thermal cooling device pointer.
*
* This interface function unregisters the "thermal-cpufreq-%x" cooling device.
*/
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
{
struct cpufreq_cooling_device *cpufreq_dev;
if (!cdev)
return;
cpufreq_dev = cdev->devdata;
mutex_lock(&cooling_cpufreq_lock);
list_del(&cpufreq_dev->node);
/* Unregister the notifier for the last cpufreq cooling device */
if (list_empty(&cpufreq_dev_list))
cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);
mutex_unlock(&cooling_cpufreq_lock);
thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
release_idr(&cpufreq_idr, cpufreq_dev->id);
kfree(cpufreq_dev->freq_table);
kfree(cpufreq_dev);
}
EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);