platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs
Siemens industrial PCs unfortunately can not always be properly identified the way we used to. An earlier commit introduced code that allows proper identification without looking at DMI strings that could differ based on product branding. Switch over to that proper way and revert commits that used to collect the machines based on unstable strings. Fixes:648e921888
("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") Fixes:e8796c6c69
("platform/x86: pmc_atom: Add Siemens CONNECT ...") Fixes:f110d252ae
("platform/x86: pmc_atom: Add Siemens SIMATIC ...") Fixes:ad0d315b4d
("platform/x86: pmc_atom: Add Siemens SIMATIC ...") Tested-by: Michael Haener <michael.haener@siemens.com> Signed-off-by: Henning Schild <henning.schild@siemens.com> Link: https://lore.kernel.org/r/20211213120502.20661-5-henning.schild@siemens.com Reviewed-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
This commit is contained in:
parent
2ebd32ce2a
commit
4ba0b8187d
1 changed files with 33 additions and 21 deletions
|
@ -13,6 +13,7 @@
|
|||
#include <linux/io.h>
|
||||
#include <linux/platform_data/x86/clk-pmc-atom.h>
|
||||
#include <linux/platform_data/x86/pmc_atom.h>
|
||||
#include <linux/platform_data/x86/simatic-ipc.h>
|
||||
#include <linux/platform_device.h>
|
||||
#include <linux/pci.h>
|
||||
#include <linux/seq_file.h>
|
||||
|
@ -362,6 +363,30 @@ static void pmc_dbgfs_register(struct pmc_dev *pmc)
|
|||
}
|
||||
#endif /* CONFIG_DEBUG_FS */
|
||||
|
||||
static bool pmc_clk_is_critical = true;
|
||||
|
||||
static int dmi_callback(const struct dmi_system_id *d)
|
||||
{
|
||||
pr_info("%s critclks quirk enabled\n", d->ident);
|
||||
|
||||
return 1;
|
||||
}
|
||||
|
||||
static int dmi_callback_siemens(const struct dmi_system_id *d)
|
||||
{
|
||||
u32 st_id;
|
||||
|
||||
if (dmi_walk(simatic_ipc_find_dmi_entry_helper, &st_id))
|
||||
goto out;
|
||||
|
||||
if (st_id == SIMATIC_IPC_IPC227E || st_id == SIMATIC_IPC_IPC277E)
|
||||
return dmi_callback(d);
|
||||
|
||||
out:
|
||||
pmc_clk_is_critical = false;
|
||||
return 1;
|
||||
}
|
||||
|
||||
/*
|
||||
* Some systems need one or more of their pmc_plt_clks to be
|
||||
* marked as critical.
|
||||
|
@ -370,6 +395,7 @@ static const struct dmi_system_id critclk_systems[] = {
|
|||
{
|
||||
/* pmc_plt_clk0 is used for an external HSIC USB HUB */
|
||||
.ident = "MPL CEC1x",
|
||||
.callback = dmi_callback,
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"),
|
||||
DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"),
|
||||
|
@ -378,6 +404,7 @@ static const struct dmi_system_id critclk_systems[] = {
|
|||
{
|
||||
/* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */
|
||||
.ident = "Lex 3I380D",
|
||||
.callback = dmi_callback,
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
|
||||
DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
|
||||
|
@ -386,6 +413,7 @@ static const struct dmi_system_id critclk_systems[] = {
|
|||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Lex 2I385SW",
|
||||
.callback = dmi_callback,
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
|
||||
DMI_MATCH(DMI_PRODUCT_NAME, "2I385SW"),
|
||||
|
@ -394,30 +422,17 @@ static const struct dmi_system_id critclk_systems[] = {
|
|||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Beckhoff Baytrail",
|
||||
.callback = dmi_callback,
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
|
||||
DMI_MATCH(DMI_PRODUCT_FAMILY, "CBxx63"),
|
||||
},
|
||||
},
|
||||
{
|
||||
.ident = "SIMATIC IPC227E",
|
||||
.ident = "SIEMENS AG",
|
||||
.callback = dmi_callback_siemens,
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
|
||||
DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
|
||||
},
|
||||
},
|
||||
{
|
||||
.ident = "SIMATIC IPC277E",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
|
||||
DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"),
|
||||
},
|
||||
},
|
||||
{
|
||||
.ident = "CONNECT X300",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
|
||||
DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588"),
|
||||
},
|
||||
},
|
||||
|
||||
|
@ -429,7 +444,6 @@ static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
|
|||
{
|
||||
struct platform_device *clkdev;
|
||||
struct pmc_clk_data *clk_data;
|
||||
const struct dmi_system_id *d = dmi_first_match(critclk_systems);
|
||||
|
||||
clk_data = kzalloc(sizeof(*clk_data), GFP_KERNEL);
|
||||
if (!clk_data)
|
||||
|
@ -437,10 +451,8 @@ static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
|
|||
|
||||
clk_data->base = pmc_regmap; /* offset is added by client */
|
||||
clk_data->clks = pmc_data->clks;
|
||||
if (d) {
|
||||
clk_data->critical = true;
|
||||
pr_info("%s critclks quirk enabled\n", d->ident);
|
||||
}
|
||||
if (dmi_check_system(critclk_systems))
|
||||
clk_data->critical = pmc_clk_is_critical;
|
||||
|
||||
clkdev = platform_device_register_data(&pdev->dev, "clk-pmc-atom",
|
||||
PLATFORM_DEVID_NONE,
|
||||
|
|